مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,029
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATION OF DISPERSIVE LIQUID-LIQUID MICROEXTRACTION ON THE LONG THIN TUBE FOR EXTRACTION AND CONCENTRATION OF ORGANOCHLORINE COMPOUNDS IN THE RIVER WATER AND MEASURING BY GAS CHROMATOGRAPHY

Pages

  133-144

Abstract

 This article examines a simple and efficient method for extraction and preconcentration at the same time very low values of ORGANOCHLORINE (OCPS) in the river water samples, based on the specific situation of DISPERSIVE LIQUID-liquid microextraction in a long thin tube. The effect of influencing factors in microextraction such as the type and volume of solvents dispersive and extracted and volume of sample aqueous solution was studied and optimized. In the optimized qualification, mixture of 2.5 ml acetone and 0.5 ml n-hexane and toluene (1:1) for 30 seconds to 19 ml water solution is injected into the pipe and formed cloudy solution and toxins transferred to the organic phase and reached the top of the column. Finally, after extraction and cleanup 1 ul of samples injected into GAS CHROMATOGRAPHY FLAME IONIZATION and compared to standard solutions curve, were determined. Under optimal conditions, the linear range of calibration curves in the range of 0.6 to 1.4 ug/ml and relative recovery of 93.1 to 98.6, relative standard deviation much lower than 5.9% and correlation coefficient of 0.95 was calculated. The limit of detection and quantification limits, respectively, in the range of 0.8 to 1.3 and 3.1 to 3.7 ug/l respectively. The advantage of this method is the simplicity, speed, low cost and high recovery percentage.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    YUSEFZADE, SH., ASGHARI KALJAHI, E., AMEL, N., GOLBABAZADEH, T., & SABERI, H.. (2016). EVALUATION OF DISPERSIVE LIQUID-LIQUID MICROEXTRACTION ON THE LONG THIN TUBE FOR EXTRACTION AND CONCENTRATION OF ORGANOCHLORINE COMPOUNDS IN THE RIVER WATER AND MEASURING BY GAS CHROMATOGRAPHY. JOURNAL OF APPLIED CHEMISTRY, 11(40), 133-144. SID. https://sid.ir/paper/243334/en

    Vancouver: Copy

    YUSEFZADE SH., ASGHARI KALJAHI E., AMEL N., GOLBABAZADEH T., SABERI H.. EVALUATION OF DISPERSIVE LIQUID-LIQUID MICROEXTRACTION ON THE LONG THIN TUBE FOR EXTRACTION AND CONCENTRATION OF ORGANOCHLORINE COMPOUNDS IN THE RIVER WATER AND MEASURING BY GAS CHROMATOGRAPHY. JOURNAL OF APPLIED CHEMISTRY[Internet]. 2016;11(40):133-144. Available from: https://sid.ir/paper/243334/en

    IEEE: Copy

    SH. YUSEFZADE, E. ASGHARI KALJAHI, N. AMEL, T. GOLBABAZADEH, and H. SABERI, “EVALUATION OF DISPERSIVE LIQUID-LIQUID MICROEXTRACTION ON THE LONG THIN TUBE FOR EXTRACTION AND CONCENTRATION OF ORGANOCHLORINE COMPOUNDS IN THE RIVER WATER AND MEASURING BY GAS CHROMATOGRAPHY,” JOURNAL OF APPLIED CHEMISTRY, vol. 11, no. 40, pp. 133–144, 2016, [Online]. Available: https://sid.ir/paper/243334/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top