مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

317
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

484
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

STRENGTHENING DESIGN LIMITATIONS OF AN RC FRAMES USING FRP COLUMN WRAPPING CONSIDERING COLUMN-TO-BEAM STRENGTH RATIO

Pages

  405-413

Keywords

Not Registered.

Abstract

 The aim of this paper is to study the influence of the column-to-beam strength ratio on the seismic strengthening of a column with a Fiber-Reinforced Plastic (FRP) wrapping system. FRP wrapped Reinforced Concrete (RC) columns are analyzed to obtain moment-curvature curves using FRP confined concrete characteristics. A pushover analysis of a 2D model was performed on one and three-story moment-resisting frames, with different column-to-beam strength ratios. The results indicate that FRP strengthening is more efficient in frames with a low ratio of column-to-beam strength, due to the type of lateral failure mechanism of the frame. Also, high values of the column-to-beam strength ratio can be benefited by low values of the confining pressure. In case of column strength greater than beam strength, beyond a certain confining pressure ratio, further enhancement in performance will not be achieved. Therefore, the level of effective wrapping on frame performance enhancement is controlled by the column-to-beam strength ratio.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    KHALOU, A.R., & ESMAEELI, A.. (2007). STRENGTHENING DESIGN LIMITATIONS OF AN RC FRAMES USING FRP COLUMN WRAPPING CONSIDERING COLUMN-TO-BEAM STRENGTH RATIO. SCIENTIA IRANICA, 14(5), 405-413. SID. https://sid.ir/paper/289565/en

    Vancouver: Copy

    KHALOU A.R., ESMAEELI A.. STRENGTHENING DESIGN LIMITATIONS OF AN RC FRAMES USING FRP COLUMN WRAPPING CONSIDERING COLUMN-TO-BEAM STRENGTH RATIO. SCIENTIA IRANICA[Internet]. 2007;14(5):405-413. Available from: https://sid.ir/paper/289565/en

    IEEE: Copy

    A.R. KHALOU, and A. ESMAEELI, “STRENGTHENING DESIGN LIMITATIONS OF AN RC FRAMES USING FRP COLUMN WRAPPING CONSIDERING COLUMN-TO-BEAM STRENGTH RATIO,” SCIENTIA IRANICA, vol. 14, no. 5, pp. 405–413, 2007, [Online]. Available: https://sid.ir/paper/289565/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button