مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

498
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

197
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A Sensitive determination of Rutin at Fe3O4@SiO2 [FS-MCPE] – A Voltammetric Study

Pages

  506-520

Abstract

 An electrochemical sensor was developed by decorating a newly synthesized iron oxide magnetite nanoparticle capped silica dioxide (Fe3O4@SiO2 microspheres) on the surface of carbon paste electrode. The developed sensor was further used in the electrochemical determination of Rutin (Vitamin P). Cyclic and differential pulse voltammetric methods were carried out to study the kinetic parameters and the quantitative determination of Rutin respectively. Phosphate buffer solution (0. 1 M) with pH 7. 5 was used as supporting electrolyte in the present investigation. Various parameters like effect of pH, effect of concentration and effect of scan rate were studied in a systematic manner. A set of cyclic voltammogram redox peaks of Rutin was appeared at 397. 2 mV (Epa) and 367. 8 mV (Epc). The anodic peak currents were linearly increased with increase in the concentration of Rutin with a dynamic range of 1. 6×10− 6-1. 6×10− 5 M. The detection limit was calculated and found to be 1. 43×10− 6 M. Electrochemical parameters viz., number of electrons transferred (n), electrode reaction rate constant (ks), and the charge transfer coefficient (α ), were calculated and found to be 2. 0, 0. 00149 and 1. 09 respectively. Further the developed novel electrochemical sensor was successfully applied for the determination of real samples analysis. The results concluded that the Fe3O4@SiO2 modified carbon paste electrode (FS-MCPE) has showed the long lasting stability, high sensitivity and low detection limits, towards the determination of Rutin.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button