مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

393
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Experimental study and Numerical Optimization for the Burner Geometry Parameters of Preheated Furnace at Esfarayen Steel Industrial Complex

Pages

  479-488

Abstract

 In this research, the geometric parameters of a preheated furnace Burner in the press line of Esfarayen Industrial Complex have been studied, experimentally and numerically. To improve the Combustion process in the Burner, three different diameters (10, 20, and 30 mm) are provided for the nozzle diameter and three different lengths (225, 250, and 300 mm) for the mixing length of the Burner. Ansys-Fluent software and RNG k-ε turbulence model have been used for the simulation and the modeling results show that the applied method has good accuracy and with a maximum error of 23% higher than the experimental values for temperature. This temperature difference is due to the lack of accurate measurement of inlet airflow and also point measurement of temperature in the Burner. In the study of the effect of nozzle diameter, it was observed that by increasing the nozzle diameter from 10 to 30 mm, the maximum temperature inside the Burner increased by 6%, which against a slight increase in nitrogen oxides (Nox) pollutants inside the Burner, the 30 mm diameter for optimum design is selected among the tested diameters. Also, the results of the study for the effect of mixing length on Burner performance have shown that by increasing the length, the amount of heat produced decreases slightly, which due to more favorable stability of NOx pollutants due to more space and complete reaction, length of 300 mm has been chosen for the optimal design of the Burner.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HATAMI, M., & GHOLIPOUR, A.. (2021). Experimental study and Numerical Optimization for the Burner Geometry Parameters of Preheated Furnace at Esfarayen Steel Industrial Complex. MODARES MECHANICAL ENGINEERING, 21(7 ), 479-488. SID. https://sid.ir/paper/374095/en

    Vancouver: Copy

    HATAMI M., GHOLIPOUR A.. Experimental study and Numerical Optimization for the Burner Geometry Parameters of Preheated Furnace at Esfarayen Steel Industrial Complex. MODARES MECHANICAL ENGINEERING[Internet]. 2021;21(7 ):479-488. Available from: https://sid.ir/paper/374095/en

    IEEE: Copy

    M. HATAMI, and A. GHOLIPOUR, “Experimental study and Numerical Optimization for the Burner Geometry Parameters of Preheated Furnace at Esfarayen Steel Industrial Complex,” MODARES MECHANICAL ENGINEERING, vol. 21, no. 7 , pp. 479–488, 2021, [Online]. Available: https://sid.ir/paper/374095/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button