مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

379
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

The feasibility of using microstrip gas detector as radon detector for earthquake prediction

Pages

  25-32

Abstract

 In the last decade, several studies have concluded that elevated concentrations of Radon gas in soil or groundwater could be the sign of an imminent Earthquake. It is believed that in case of sudden movement of rocks before Earthquake, Radon is released from the depth of ground and reached the surface. In this way, by measuring Radon concentration change, Earthquake prediction is possible. In this study, for the purpose of the feasibility of using Microstrip gas detector in monitoring Radon change, initially for the verification of the code, the range of Radon alpha particles and its progeny in the air has been obtained in the standard condition, which is consistent with the experimental results. Then detector geometry has been simulated by MCNPX code and after examining the average of detector response to decay, the output code is calibrated considering the information about the Radon changes in Jowshan hot spring. The results have shown that the detector response is comparable to the experimental data and can be used as an Earthquake pre-indicator.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Dehghanipour, Parvin, Soltani nabipour, Jamshid, SOHRABI, MEHDI, Rezaei Raeini nejad, Mohammadreza, & Hashemizadeh Aghda, Ali. (2019). The feasibility of using microstrip gas detector as radon detector for earthquake prediction. IRANIAN JOURNAL OF RADIATION SAFETY AND MEASUREMENT, 8(4 (supplement) ), 25-32. SID. https://sid.ir/paper/379438/en

    Vancouver: Copy

    Dehghanipour Parvin, Soltani nabipour Jamshid, SOHRABI MEHDI, Rezaei Raeini nejad Mohammadreza, Hashemizadeh Aghda Ali. The feasibility of using microstrip gas detector as radon detector for earthquake prediction. IRANIAN JOURNAL OF RADIATION SAFETY AND MEASUREMENT[Internet]. 2019;8(4 (supplement) ):25-32. Available from: https://sid.ir/paper/379438/en

    IEEE: Copy

    Parvin Dehghanipour, Jamshid Soltani nabipour, MEHDI SOHRABI, Mohammadreza Rezaei Raeini nejad, and Ali Hashemizadeh Aghda, “The feasibility of using microstrip gas detector as radon detector for earthquake prediction,” IRANIAN JOURNAL OF RADIATION SAFETY AND MEASUREMENT, vol. 8, no. 4 (supplement) , pp. 25–32, 2019, [Online]. Available: https://sid.ir/paper/379438/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button