مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

692
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ASSESSMENT OF STAFF EXPOSURE TO RADON IN RADIOTHERAPY CENTERS IN TEHRAN, 2015

Author(s)

IMANI AREZOO | MIANJI FEREIDOUN | CHANGIZI VAHID | MOUSAVIE ANIJDAN SEYYED HOSSEIN | PAYDAR REZA | Issue Writer Certificate 

Pages

  342-350

Abstract

 Background and Aim: Estimation of RADON density in underground centers is very important. Considering the use of high-energy medical accelerators, RADIOTHERAPY departments are usually located in underground floors. The aim of this study was to evaluate staff exposure to RADON gas in these centers in Tehran in 2015-2016.Materials and Methods: This is a descriptive, cross-sectional survey. In RADIOTHERAPY centers of Tehran, 32 RADON gas diffusion chamber detectors were installed for a period of 3 months. After collecting the detectors, RADON gas concentrations were calculated. The annual EFFECTIVE DOSE of personnel was evaluated using staff’s working hours per week.Results: The minimum and maximum concentrations recorded in this study during one year were 22.14 and 398.52 Bq/m3, respectively, with an average of 87.01 ±80.68 Bq/m3. Also, RADIOTHERAPY personnel’s annual EFFECTIVE DOSE was 0.34 ± 0.43 mSv per year with the minimum and maximum amounts of 0.02 and 2.35 mSv per year, respectively.Conclusion: The results indicate that RADON level in RADIOTHERAPY centers and also that the annual EFFECTIVE DOSE of personnel in these centers are permissible, and no special action is needed. However, if more attention is paid to certain factors such as air-conditioning, the amount of the gas can even be brought to less than this limit.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    IMANI, AREZOO, MIANJI, FEREIDOUN, CHANGIZI, VAHID, MOUSAVIE ANIJDAN, SEYYED HOSSEIN, & PAYDAR, REZA. (2017). ASSESSMENT OF STAFF EXPOSURE TO RADON IN RADIOTHERAPY CENTERS IN TEHRAN, 2015. PAYAVARD-SALAMAT, 11(3 ), 342-350. SID. https://sid.ir/paper/149655/en

    Vancouver: Copy

    IMANI AREZOO, MIANJI FEREIDOUN, CHANGIZI VAHID, MOUSAVIE ANIJDAN SEYYED HOSSEIN, PAYDAR REZA. ASSESSMENT OF STAFF EXPOSURE TO RADON IN RADIOTHERAPY CENTERS IN TEHRAN, 2015. PAYAVARD-SALAMAT[Internet]. 2017;11(3 ):342-350. Available from: https://sid.ir/paper/149655/en

    IEEE: Copy

    AREZOO IMANI, FEREIDOUN MIANJI, VAHID CHANGIZI, SEYYED HOSSEIN MOUSAVIE ANIJDAN, and REZA PAYDAR, “ASSESSMENT OF STAFF EXPOSURE TO RADON IN RADIOTHERAPY CENTERS IN TEHRAN, 2015,” PAYAVARD-SALAMAT, vol. 11, no. 3 , pp. 342–350, 2017, [Online]. Available: https://sid.ir/paper/149655/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button