مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

169
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

115
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Dosimetric investigation of esophageal stents carrying I-125 seeds for the treatment of advanced esophageal cancer

Pages

  27-33

Abstract

Radioactive stents loaded with I-125 seeds have been widely used for the treatment of advanced Esophageal cancer. Understanding the dose distribution of such stents before the clinical use is essential. This study provides a dosimetric investigation of I-125 seed-loaded stents based on the seed’ s arrangement and activity. A cylindrical water equivalent phantom with an esophageal stent loaded with I-125 seeds, were employed. The seeds arrangements were determined based on the distance between the centers of two adjacent seeds (z) along the stent length. EBT3 fi lms as well as Geant4 Monte Carlo toolkit were used to obtain the dose distribution around the stent. By modeling the MIRD phantom, the dose delivered to the related organs at risk was calculated. The appropriate dose distribution is achieved for z = 15 mm, in which the absorbed dose at a depth of 5 mm reaches about 45% of the absorbed dose near the stent surface, thereby the therapeutic dose is delivered to the reference points. Both arrangements (z = 15 and 20 mm) seemed to be clinically eligible and their utilization depends on the patient and the hospital facilities. Using esophageal stents with z > 20 mm is not recommended due to the presence of cold spots in the dose distribution.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Rafipour, Payman, SHEIBANI, SHAHAB, Rezaey Uchbelagh, Daryiush, & Poorbaygi, Hossein. (2021). Dosimetric investigation of esophageal stents carrying I-125 seeds for the treatment of advanced esophageal cancer. RADIATION PHYSICS AND ENGINEERING, 2(1), 27-33. SID. https://sid.ir/paper/759576/en

    Vancouver: Copy

    Rafipour Payman, SHEIBANI SHAHAB, Rezaey Uchbelagh Daryiush, Poorbaygi Hossein. Dosimetric investigation of esophageal stents carrying I-125 seeds for the treatment of advanced esophageal cancer. RADIATION PHYSICS AND ENGINEERING[Internet]. 2021;2(1):27-33. Available from: https://sid.ir/paper/759576/en

    IEEE: Copy

    Payman Rafipour, SHAHAB SHEIBANI, Daryiush Rezaey Uchbelagh, and Hossein Poorbaygi, “Dosimetric investigation of esophageal stents carrying I-125 seeds for the treatment of advanced esophageal cancer,” RADIATION PHYSICS AND ENGINEERING, vol. 2, no. 1, pp. 27–33, 2021, [Online]. Available: https://sid.ir/paper/759576/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button