مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Seminar Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

106
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

73
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Seminar Paper

Title

THE EFFECT OF THE HEAT LOADS ON THE PARTIAL-VACUUM THERMOSYPHON PERFORMANCE

Pages

  -

Abstract

 IN THE PRESENT RESEARCH, THE EFFECT OF THE HEAT FLUX AND THE COOLING WATER FLOW RATE OF THE CONDENSER ON OVERALL PERFORMANCE OF PARTIALLY VACUUMED THERMOSYPHON WERE STUDIED. A RIG WAS MADE FROM A 1 M COPPER TUBE WITH AN INSIDE AND AN OUTSIDE DIAMETER OF 17.5 AND 19 MM. THE HEIGHTS OF THE EVAPORATOR, THE ADIABATIC SECTION AND THE CONDENSER ARE 40, 20 AND 40 CM RESPECTIVELY. THE TEMPERATURES AT DIFFERENT PLACES ON THE THERMOSYPHON AND ON THE INLET/OUTLET OF THE COOLING WATER WERE MEASURED. IT WAS OBSERVED THAT WITH INCREASING OF HEAT FLUX TO THE EVAPORATOR THE THERMOSYPHON PERFORMANCE INCREASED. ON THE OTHER HAND, WITH DECREASING OF THE COOLING WATER FLOW RATE, THE PERFORMANCE OF THE THERMOSYPHON WAS INCREASED AS THE TRAPPED AIR MOVED TOWARD THE END OF THE CONDENSER. IN ORDER TO ILLUSTRATE THE EFFECT OF EXISTENCE OF AIR TO DEACTIVATING THE THERMOSYPHON, THE PIPE WAS COOL DOWN BY DISCONNECTING OF POWER INPUT TO THE EVAPORATOR. IT WAS SEEN THAT THE THERMOSYPHON LOSS ITS PERFORMANCE AS THE TRAPPED GAS OCCUPIES THE WHOLE CONDENSER. THE WHOLE STUDY SHOWS DUE TO EXISTENCE OF AIR, THE HEAT LOADS CAN HAVE SIGNIFICANT EFFECTS ON THE PERFORMANCE OF THE THERMOSYPHON.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    RAHIMI, MASOUD. (2008). THE EFFECT OF THE HEAT LOADS ON THE PARTIAL-VACUUM THERMOSYPHON PERFORMANCE. INTERNATIONAL CHEMICAL ENGINEERING CONGRESS AND EXHIBITION. SID. https://sid.ir/paper/908617/en

    Vancouver: Copy

    RAHIMI MASOUD. THE EFFECT OF THE HEAT LOADS ON THE PARTIAL-VACUUM THERMOSYPHON PERFORMANCE. 2008. Available from: https://sid.ir/paper/908617/en

    IEEE: Copy

    MASOUD RAHIMI, “THE EFFECT OF THE HEAT LOADS ON THE PARTIAL-VACUUM THERMOSYPHON PERFORMANCE,” presented at the INTERNATIONAL CHEMICAL ENGINEERING CONGRESS AND EXHIBITION. 2008, [Online]. Available: https://sid.ir/paper/908617/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button