مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

747
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DOSIMETRY OF 186RE RADIOISOTOPE IN INTRAVASCULAR BRACHYTHERAPY TO REDUCE VASCULAR RESTENOSIS

Pages

  10-16

Abstract

 Recently, the use of filled angioplasty balloon with radioactive solution was proposed as one of the new intravascular irradiation techniques to reduce RESTENOSIS. Measurement of dose distribution beyond an angioplasty balloon filled with 186Re-perrhenatewas carried out using a RADIOCHROMIC FILM. The measured dose rate in distance of 0.4mm from the balloon surface (with diameter 4mm and length of 40mm) was 2.07 [(cGy/min)/(mCi/ml)]. Calculation of dose was carried out for the balloons with various size, using MONTE-CARLO METHOD with MCNP4B code and the result was comparable with the experimental results. Suitable specific concentrations for delivery of doses from 12 to 20 Gy in vessel wall were obtained 250 to 400(mCi/ml) in the time of irradiation less than 4min and the fall of radial dose was obtained approximately 80 percent in radial distance of 0.5mm from the balloon surface. The internal dose was calculated by MIRD method with assuming that in the case of balloon rupture, 186Re-DTPAcontents were released into the circulation system and was about 0.0027 cGy/MBq which is comparable with the 99mTc-DTP Amodel. Therefore, using from 186Re-DTPA is suitable due to the radiation safety and the delivery of dose in order to reduce RESTENOSIS for the coronary vessels with centric cross section.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    POURBEYGI, H., SHEYBANI, SH., GHAFORIAN, HOSSEIN, & GHAHRAMANI, M.R.. (2006). DOSIMETRY OF 186RE RADIOISOTOPE IN INTRAVASCULAR BRACHYTHERAPY TO REDUCE VASCULAR RESTENOSIS. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, -(2 (37)), 10-16. SID. https://sid.ir/paper/97711/en

    Vancouver: Copy

    POURBEYGI H., SHEYBANI SH., GHAFORIAN HOSSEIN, GHAHRAMANI M.R.. DOSIMETRY OF 186RE RADIOISOTOPE IN INTRAVASCULAR BRACHYTHERAPY TO REDUCE VASCULAR RESTENOSIS. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY[Internet]. 2006;-(2 (37)):10-16. Available from: https://sid.ir/paper/97711/en

    IEEE: Copy

    H. POURBEYGI, SH. SHEYBANI, HOSSEIN GHAFORIAN, and M.R. GHAHRAMANI, “DOSIMETRY OF 186RE RADIOISOTOPE IN INTRAVASCULAR BRACHYTHERAPY TO REDUCE VASCULAR RESTENOSIS,” JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, vol. -, no. 2 (37), pp. 10–16, 2006, [Online]. Available: https://sid.ir/paper/97711/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button