مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

414
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Comparative Study of Noise Reduction in MRI Images Using Filtering and Wavelet Transform in Medical Image Processing

Pages

  60-68

Abstract

 Background and Aim: Noise reduction in medical images is important. Excessive distortion in medical images reduces the accuracy of diagnosis of various diseases or structures. Violet conversion and Filtering are among the most widely used methods for reducing noise in medical images. The aim of this study was to compare Noise reduction using filtration (low-pass, mid-pass, and high-pass filters) as well as violet conversion from MRI images. Methods: In this study, using MATLAB software, noisy MRI data were entered into the program environment and each of the proposed algorithms including Filtering (low-pass, mid-pass, and high-pass filters) as well as violet conversion were implemented separately on images. And the ideal output was obtained due to the nature of the noise. Results: The results obtained from the proposed violet and Filtering methods were compared and analyzed. The signal-to-noise ratio (SNR) of all filters used and the violet conversion displayed a value above 30 dB. Violet conversion for selected images has a higher SNR value, and in some images, this difference is more than 40 dB. According to the images and relative PSNR values, among all the studied methods, the best dehumidification is when the CWT method was used. In this case, the PSNR is high and there is the most similarity between the degenerate image and the original image.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    shahalinejad, Sahand, Bahadori, Atefeh, & NIAPOUR, ALI. (2023). Comparative Study of Noise Reduction in MRI Images Using Filtering and Wavelet Transform in Medical Image Processing. ALBORZ UNIVERSITY MEDICAL JOURNAL, 12(1 ), 60-68. SID. https://sid.ir/paper/1018767/en

    Vancouver: Copy

    shahalinejad Sahand, Bahadori Atefeh, NIAPOUR ALI. Comparative Study of Noise Reduction in MRI Images Using Filtering and Wavelet Transform in Medical Image Processing. ALBORZ UNIVERSITY MEDICAL JOURNAL[Internet]. 2023;12(1 ):60-68. Available from: https://sid.ir/paper/1018767/en

    IEEE: Copy

    Sahand shahalinejad, Atefeh Bahadori, and ALI NIAPOUR, “Comparative Study of Noise Reduction in MRI Images Using Filtering and Wavelet Transform in Medical Image Processing,” ALBORZ UNIVERSITY MEDICAL JOURNAL, vol. 12, no. 1 , pp. 60–68, 2023, [Online]. Available: https://sid.ir/paper/1018767/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button