مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,566
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ESTIMATING THE MAXIMUM AEROBIC CAPACITY OF FIRE FIGHTERS USING THE STEP TEST, A CASE STUDY WITH HEIGHT ADJUSTABLE STEPS

Pages

  60-65

Abstract

 Introduction: Firefighting is amongst jobs that require high physical strength and high aerobic capacity. These are required because of the nature and the physical demands of the job. The maximum aerobic capacities of FIREFIGHTERS were investigated using the STEP TEST.Methods: This cross-sectional descriptive-analytical study was conducted on 73 FIREFIGHTERS. At first, demographic information was collected by a questionnaire. Then, the step was built with adjustable height, for STEP TESTing, and using the Francis method, MAXIMUM AEROBIC CAPACITY of the participants, was studied. The results of the questionnaire and STEP TEST were analyzed by the SPSS 16 software.Results: MAXIMUM AEROBIC CAPACITY of FIREFIGHTERS was calculated as 3.65 L/min and 47.4 mL/kgmin. Moreover, the results of statistical analysis revealed a significant relationship between body mass index and exercise, and MAXIMUM AEROBIC CAPACITY (P<0.05). Also no significant relationship was found between MAXIMUM AEROBIC CAPACITY, age, smoking and work-related fatigue (P>0.05).Conclusions: Studying the FIREFIGHTERS cardiorespiratory capacity, to reduce the probability of FIREFIGHTERS injuries is very important due to occupational sensitivity and having to perform difficult tasks under demanding circumstances. The results of this study showed that maximal oxygen uptake (vo2 max) and cardiopulmonary capacity of examined FIREFIGHTERS are greater than the minimum amount recommended by the international association of FIREFIGHTERS, which can be due to regular physical fitness programs conducted by the organization.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    FARHADI, SAJJAD, HESAM, GHASEM, MORADPOUR, ZAHRA, ABAZARI, MALEK, & BABAYI MESDARAGHI, YOUSEF. (2016). ESTIMATING THE MAXIMUM AEROBIC CAPACITY OF FIRE FIGHTERS USING THE STEP TEST, A CASE STUDY WITH HEIGHT ADJUSTABLE STEPS. JOURNAL OF ERGONOMICS, 4(2), 60-65. SID. https://sid.ir/paper/103247/en

    Vancouver: Copy

    FARHADI SAJJAD, HESAM GHASEM, MORADPOUR ZAHRA, ABAZARI MALEK, BABAYI MESDARAGHI YOUSEF. ESTIMATING THE MAXIMUM AEROBIC CAPACITY OF FIRE FIGHTERS USING THE STEP TEST, A CASE STUDY WITH HEIGHT ADJUSTABLE STEPS. JOURNAL OF ERGONOMICS[Internet]. 2016;4(2):60-65. Available from: https://sid.ir/paper/103247/en

    IEEE: Copy

    SAJJAD FARHADI, GHASEM HESAM, ZAHRA MORADPOUR, MALEK ABAZARI, and YOUSEF BABAYI MESDARAGHI, “ESTIMATING THE MAXIMUM AEROBIC CAPACITY OF FIRE FIGHTERS USING THE STEP TEST, A CASE STUDY WITH HEIGHT ADJUSTABLE STEPS,” JOURNAL OF ERGONOMICS, vol. 4, no. 2, pp. 60–65, 2016, [Online]. Available: https://sid.ir/paper/103247/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button