مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

47
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CALCULATION OF THE EFFECT OF BETA BEAMS, BREMSSTRAHLUNG X-RAY, AND THE USE OF 10B PARTICLES ON INCREASING DOSE EQUIVALENT TO 252CF BRACHYTHERAPY SOURCE

Pages

  441-450

Abstract

 Background & Aims: 252Cf is a source of emission of neutron, gamma rays, and beta and alpha particles. In the common models of this source used in brachytherapy, only neutrons and gamma rays contribute in the dosimetry around the source. In this study, while investigating the escape of beta rays and Bremsstrahlung X-Rays from the source capsule of brachytherapy 252Cf of Isotron model, the dosimetry of the total effective radiation in the water environment around the source was performed and the total Equivalent Dose increase was calculated using 10B Particles. Materials & Methods: Dosimetry for the neutron rays, the primary gammas, the secondary gammas, the beta particles, and the Bremsstrahlung X-Rays in the spherical water phantom performed with the radius of 20 cm at the distances of 0. 5 to 6 cm from the source using the Monte Carlo MCNPX. 2. 6. 0 code. Dose increment factor was calculated using B10 particles with a concentration of 50 ppm. Results: The highest relative difference in dose values, taking into account the X-ray and the beta particles their absence at the distance of 0. 5 cm from the source, was %19. As the distance from the source increases, the effect of these rays on the total Equivalent Dose rate decrease, as in the distance of 2. 5 cm distance, its values reach less than % 0. 5. The boron effect on the total Equivalent Dose increases by distance from the source, as at the 0. 5 to 6 cm distances from the source will increase from %0. 01 to more than % 22. Conclusion: According to the findings of this study, the dose of the X-rays and the beta particles passing through the source capsule are effective in the dosimetry around the source, and increasing the dose by 10B depends on increasing the tumor source distance, which should be considered in clinical applications.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    AHMADI, OME LEILA, & TAVAKOLI ANBARAN, HOSSEIN. (2022). CALCULATION OF THE EFFECT OF BETA BEAMS, BREMSSTRAHLUNG X-RAY, AND THE USE OF 10B PARTICLES ON INCREASING DOSE EQUIVALENT TO 252CF BRACHYTHERAPY SOURCE. STUDIES IN MEDICAL SCIENCE (THE JOURNAL OF URMIA UNIVERSITY OF MEDICAL SCINCES), 33(6), 441-450. SID. https://sid.ir/paper/1081464/en

    Vancouver: Copy

    AHMADI OME LEILA, TAVAKOLI ANBARAN HOSSEIN. CALCULATION OF THE EFFECT OF BETA BEAMS, BREMSSTRAHLUNG X-RAY, AND THE USE OF 10B PARTICLES ON INCREASING DOSE EQUIVALENT TO 252CF BRACHYTHERAPY SOURCE. STUDIES IN MEDICAL SCIENCE (THE JOURNAL OF URMIA UNIVERSITY OF MEDICAL SCINCES)[Internet]. 2022;33(6):441-450. Available from: https://sid.ir/paper/1081464/en

    IEEE: Copy

    OME LEILA AHMADI, and HOSSEIN TAVAKOLI ANBARAN, “CALCULATION OF THE EFFECT OF BETA BEAMS, BREMSSTRAHLUNG X-RAY, AND THE USE OF 10B PARTICLES ON INCREASING DOSE EQUIVALENT TO 252CF BRACHYTHERAPY SOURCE,” STUDIES IN MEDICAL SCIENCE (THE JOURNAL OF URMIA UNIVERSITY OF MEDICAL SCINCES), vol. 33, no. 6, pp. 441–450, 2022, [Online]. Available: https://sid.ir/paper/1081464/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button