مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

5,045
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

SURVEY ON SCATTERED AND RECEIVED DOSE OF X-RAY RADIATION IN A MILITARY HOSPITAL

Pages

  134-142

Abstract

 Background and aims: Using X-RAY for diagnostic test is one of the most important exposures to radiation sources for general population and in particular for radiation workers. Therefore, holding down the pollution at the lowest possible level is very important for protection against the internal exposure. The objective of this study is to survey the scattered X-RAY rate and received dose by staff of ANGIOGRAPHY department in a military hospital.Methods: Present cross – sectional study was conducted in a military hospital. The scattered xray produced from different ANGIOGRAPHY modes (pulse high-dose and continuous FLUOROSCOPY) was measured in one and two meters distance of ANGIOGRAPHY set and in outside of the ANGIOGRAPHY room by using SmartION Model 2100 S. The staff received dose in 2 months, 1 year and 5 years periods, was obtained through staffs film badge results.Results: The results showed the scattered X-RAY rate in one and two meters distance from patient table for pulse mode FLUOROSCOPY was 47 and 7.9 mSVh-1 and for continuous FLUOROSCOPY was 8.9 and 4 mSVh-1 respectively. The obtained results from the personnel film badge for a period of one and five years were respectively 8.08 and 22, 85 mSV per year for physician' s staff, 1, 44 and 2, 12 mSv per year for radiologists staff and 1 and 2.55mSv per year for nurses, respectively. The dose received by all employees was less than the PERMISSIBLE LIMITs (20 mSv per year).Conclusion: The various modes of ANGIOGRAPHY, experience and expertise of the physicians and other factors can play an important role in received EFFECTIVE DOSE by staff. The staff training, optimized radiation protection practice and staff dose monitoring can be kept well below the annual received dose limit.

Cites

References

  • No record.
  • Cite

    APA: Copy

    VALIPOOR, FIROOZ, AHMADI, OMRAN, POORTAGHI, GHOLAMHOSEIN, MAHMOODI, NOROZ, & SEYED MOHAMADIAN, MOHAMAD. (2017). SURVEY ON SCATTERED AND RECEIVED DOSE OF X-RAY RADIATION IN A MILITARY HOSPITAL. IRAN OCCUPATIONAL HEALTH JOURNAL, 14(1), 134-142. SID. https://sid.ir/paper/129215/en

    Vancouver: Copy

    VALIPOOR FIROOZ, AHMADI OMRAN, POORTAGHI GHOLAMHOSEIN, MAHMOODI NOROZ, SEYED MOHAMADIAN MOHAMAD. SURVEY ON SCATTERED AND RECEIVED DOSE OF X-RAY RADIATION IN A MILITARY HOSPITAL. IRAN OCCUPATIONAL HEALTH JOURNAL[Internet]. 2017;14(1):134-142. Available from: https://sid.ir/paper/129215/en

    IEEE: Copy

    FIROOZ VALIPOOR, OMRAN AHMADI, GHOLAMHOSEIN POORTAGHI, NOROZ MAHMOODI, and MOHAMAD SEYED MOHAMADIAN, “SURVEY ON SCATTERED AND RECEIVED DOSE OF X-RAY RADIATION IN A MILITARY HOSPITAL,” IRAN OCCUPATIONAL HEALTH JOURNAL, vol. 14, no. 1, pp. 134–142, 2017, [Online]. Available: https://sid.ir/paper/129215/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button