مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,065
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECT OF SILICONE BRIM SOCKET OF TRANSFEMORAL PROSTHESIS ON PRESSURE LEVEL IN PROXIMAL WEIGHT BEARING AREAS AND COMPARING WITH CONVENTIONAL SOCKET

Pages

  119-125

Abstract

 Aims: High PRESSUREs between the stamp and the socket after mutilation and receiving a prosthetic device is one of the main problems of the persons using such prosthesis. The aim of this study was to design and make a socket with a silicone brim in the trans-femoral prosthesis, as well as to investigate the PRESSURE in the upper weight bearing areas compared to the current socket.Patient & Methods In the one-sample case study, a 38-year-old male person with unilateral (right side) traumatic trans-femoral amputation was studied. Two sockets, one made by the current method and another made with a silicone brim, were presented to the person. Using FSR (force sensing resistance) and an Arduino Due microcontroller board, a PRESSURE measurement device was used to measure the PRESSURE level.Findings: In the sensor under the inferior pubic ramus (No. 8), there were 24.9% and 50.8% PRESSURE increases in the SILICONE BRIM SOCKET than the current socket in bipedal standing and standing on the prosthetic leg, respectively. In the sensor located in the upper part of scarpa’s triangle (No. 2), there was 29.1% PRESSURE increasing on the SILICONE BRIM SOCKET standing on the prosthetic leg. In addition, in the sensor on the ischial pad (No. 7), there was %2.4 PRESSURE increasing on the SILICONE BRIM SOCKET during walking at the loading response .The lowest PRESSURE was in the femur great trochanter sensor (No. 4) in all cases and both sockets. On other points in all studied conditions, there were lower PRESSURE levels in the SILICONE BRIM SOCKET than the current socket.Conclusion: Acceptance and commitment based therapy is effective on the reduction of marital burnout components in the wives of the veterans.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    EJRAEI DOLAT ABAD, H., HAJI AGHAEI, B., JALALI, M., & SAEEDI, H.. (2016). EFFECT OF SILICONE BRIM SOCKET OF TRANSFEMORAL PROSTHESIS ON PRESSURE LEVEL IN PROXIMAL WEIGHT BEARING AREAS AND COMPARING WITH CONVENTIONAL SOCKET. IRANIAN JOURNAL OF WAR AND PUBLIC HEALTH (TEBE-E-JANBAZ), 8(2), 119-125. SID. https://sid.ir/paper/152322/en

    Vancouver: Copy

    EJRAEI DOLAT ABAD H., HAJI AGHAEI B., JALALI M., SAEEDI H.. EFFECT OF SILICONE BRIM SOCKET OF TRANSFEMORAL PROSTHESIS ON PRESSURE LEVEL IN PROXIMAL WEIGHT BEARING AREAS AND COMPARING WITH CONVENTIONAL SOCKET. IRANIAN JOURNAL OF WAR AND PUBLIC HEALTH (TEBE-E-JANBAZ)[Internet]. 2016;8(2):119-125. Available from: https://sid.ir/paper/152322/en

    IEEE: Copy

    H. EJRAEI DOLAT ABAD, B. HAJI AGHAEI, M. JALALI, and H. SAEEDI, “EFFECT OF SILICONE BRIM SOCKET OF TRANSFEMORAL PROSTHESIS ON PRESSURE LEVEL IN PROXIMAL WEIGHT BEARING AREAS AND COMPARING WITH CONVENTIONAL SOCKET,” IRANIAN JOURNAL OF WAR AND PUBLIC HEALTH (TEBE-E-JANBAZ), vol. 8, no. 2, pp. 119–125, 2016, [Online]. Available: https://sid.ir/paper/152322/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top