مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,416
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECTS OF HEMOFANE AND POLYSULFONE MEMBRANES ON HYPOXEMIA OF HEMODIALYSIS PATIENTS

Pages

  445-451

Keywords

ARTERIAL O2 SATURATIONQ3

Abstract

 Background: HYPOXEMIA is one of the most important complications of HEMODIALYSIS among patients with renal failure which is related with several factors such as type of DIALYSIS MEMBRANES. The aime of this study is to investigate the hypoxemic conditions of HEMODIALYSIS patients in terms of different DIALYSIS MEMBRANES.Materials and Methods: In this cross-over clinical trial, 29 HEMODIALYSIS patients were studied in Fatemieh Hospital in Semnan city in 2004. The arterial O2 Saturations of patients undergoing HEMODIALYSIS with polysulfone (a synthetic filter) and hemofane (a cellulose filter) were measured before and stepwisely durinng the process of dialysis and their decreasing trend were compared together.Results: The deacreases in means of arterial O2 Saturations in respectively 5, 30, 60 and 120 minutes after initiation of dialysis was more in hemofane membrane group than polyfone membrane one (P<0.001). In both groups the maximun reduction rate was in 30th and 60th minutes of dialysis period.Conclusion: Applying polysulfone membranes would result in lesser decreases in O2 Saturation percent of HEMODIALYSIS patients. Therefore, to reduce the risk of HYPOXEMIA particularely among high-risk patients, it is recommended to use this type of membrane for dialysis.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    MALEK, FARHAD, ALAAVI TOUSI, J., TAMADON, M.R., MOUSAVI, SH., MALEK, M., & GHADERI, M.. (2009). EFFECTS OF HEMOFANE AND POLYSULFONE MEMBRANES ON HYPOXEMIA OF HEMODIALYSIS PATIENTS. RESEARCHER BULLETIN OF MEDICAL SCIENCES (PEJOUHANDEH), 13(5 (65)), 445-451. SID. https://sid.ir/paper/18279/en

    Vancouver: Copy

    MALEK FARHAD, ALAAVI TOUSI J., TAMADON M.R., MOUSAVI SH., MALEK M., GHADERI M.. EFFECTS OF HEMOFANE AND POLYSULFONE MEMBRANES ON HYPOXEMIA OF HEMODIALYSIS PATIENTS. RESEARCHER BULLETIN OF MEDICAL SCIENCES (PEJOUHANDEH)[Internet]. 2009;13(5 (65)):445-451. Available from: https://sid.ir/paper/18279/en

    IEEE: Copy

    FARHAD MALEK, J. ALAAVI TOUSI, M.R. TAMADON, SH. MOUSAVI, M. MALEK, and M. GHADERI, “EFFECTS OF HEMOFANE AND POLYSULFONE MEMBRANES ON HYPOXEMIA OF HEMODIALYSIS PATIENTS,” RESEARCHER BULLETIN OF MEDICAL SCIENCES (PEJOUHANDEH), vol. 13, no. 5 (65), pp. 445–451, 2009, [Online]. Available: https://sid.ir/paper/18279/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top