مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

2,533
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

MEASUREMENT OF C- REACTIVE PROTEIN (CRP) USING MAGNETIC NANOBEADS ADD ELISA

Author(s)

BAHARIFAR H. | | | | |  | Issue Writer Certificate 

Pages

  27-33

Keywords

CRPQ3

Abstract

 Background and Objective: MAGNETIC NANOBEADs have a large surface- area-to-volume ratio, which is used for immobilized antibody. Using nanoparticles could increase the amount of antibodies in surface in comparison to ELISA. We investigated the ability of MAGNETIC NANOBEADs to evaluate CRP by colorimetric method and compared the results with ELISA.Material and Methods: This study is an applicable research conducted in Tehran University of Medical Sciences, 2012. The MAGNETIC NANOBEADs conjugated by CRP antibodies were used to measure the protein in the concentration of 1-10 ng/ml (ELISA kit levels) and 0.1- 0.01 ng/ml. After antigen measurement, the results were compared with Mann Whitney test.Results: The results in concentration of 1-10 ng/ml are not significantly different (p=0.78). But In concentrations of 0.1-0.01 ng/ml, the difference is significant (p=0.02).Conclusion: The ability of MAGNETIC NANOBEADs in measurement of low concentration of antigen is 100 times better than ELISA. Thus MAGNETIC NANOBEAD method is useful for early measurement and can easily be used in clinical laboratory.

Cites

  • No record.
  • References

  • No record.
  • Cite

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button