مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,092
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CORRELATION OF PONTIC DESIGN AND PARTIAL EDENTULOUS AREAS: A ONE YEAR CROSS SECTIONAL STUDY

Pages

  156-161

Abstract

 Background and Aim: By definition, pontic is an artificial replacement of missing tooth (teeth) which is essentially used to establish function and esthetics. In order to this fact that, pontic(s) is not completely the same as tooth (teeth) to be replaced, it may not be concern as a simple type of restoration to achieve the best result, it must be design from the esthetically and hygienically point of view as well as comfort, demand and tissue health of patient. The main purpose of this study is to investigate the PONTIC DESIGNs and their relationship to edentulous partial aras.Materials and Methods: 73 pontics in 57 patients have been included in this cross-sectional study. These patients were under treatment in the department of prosthodontics. A primary cast was achieved from each patient and then the cross-sectional contour of EDENTULOUS RIDGE was depicted. For each patient the type of PONTIC DESIGN was derived from textbook standards and then compared with the design of actual verified Prosthesis at delivery. The shape of tissue surface of each denture was determined by a low viscous impression material. The result of each comparison was recorded in a chart data set.Results: The most common PONTIC DESIGN was Modified ridge lap with frequency of 93.2%. The type of ridge was %45.2 normal, %19.2 class I, %8.2 class II and %27.4 class III, respectively. %72.6 of pontics tested have inappropriate design in tissue surface.Conclusion: It seems that in a high percentage of cases the tissue surface contour of prescribed pontics in department of prosthodontics was incorrect and more attention must be paid to the education of students and technicians

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    NIKZAD, S., AZARI, ABAS, KHOSRAVI, MAHDIEH, & NEZADI, A.. (2008). CORRELATION OF PONTIC DESIGN AND PARTIAL EDENTULOUS AREAS: A ONE YEAR CROSS SECTIONAL STUDY. JOURNAL OF DENTAL MEDICINE, 21(3 (56)), 156-161. SID. https://sid.ir/paper/25300/en

    Vancouver: Copy

    NIKZAD S., AZARI ABAS, KHOSRAVI MAHDIEH, NEZADI A.. CORRELATION OF PONTIC DESIGN AND PARTIAL EDENTULOUS AREAS: A ONE YEAR CROSS SECTIONAL STUDY. JOURNAL OF DENTAL MEDICINE[Internet]. 2008;21(3 (56)):156-161. Available from: https://sid.ir/paper/25300/en

    IEEE: Copy

    S. NIKZAD, ABAS AZARI, MAHDIEH KHOSRAVI, and A. NEZADI, “CORRELATION OF PONTIC DESIGN AND PARTIAL EDENTULOUS AREAS: A ONE YEAR CROSS SECTIONAL STUDY,” JOURNAL OF DENTAL MEDICINE, vol. 21, no. 3 (56), pp. 156–161, 2008, [Online]. Available: https://sid.ir/paper/25300/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button