مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

372
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

The effect of blood and synthetic tissue fluid on the microhardness of ProRoot MTA, OrthoMTA and RetroMTA

Pages

  136-143

Abstract

 Background and Aims: The aim of this study was to assess the microHardness of BioMTA (OrthoMTA, RetroMTA) in distances of 0. 5, 2 and 3. 5 mm from the exposed surface to Blood, phosphate buffer saline (PBS) or distilled water and to compare to that of ProRoot MTA. Materials and Methods: One hundred and thirty five semicylindrical polymethyl methacrylate were filled with either ProRoot MTA, OrthoMTA, or RetroMTA. Fifteen molds in each group were exposed to Blood, 15 molds to PBS and the other 15 to distilled water. The microHardness of the materials at 0. 5, 2 and 3. 5 mm distance from the exposed surface to phosphate-buffered saline (PBS) as a synthetic tissue fluid, Blood, and distilled water was assessed. The data were analyzed using one-way ANOVA and Tukey post hoc tests. Results: Exposure to Blood significantly decreased the microHardness of all materials at all three points of 0. 5, 2 and 3. 5 mm (P<0. 001). At level of 0. 5 and 2 mm distant from Blood, OrthoMTA showed significantly the least microHardness value; however, at the point of 3. 5 mm, the microHardness of RetroMTA was higher than the two other materials (P<0. 001). After exposure of samples to distilled water or PBS, no significant difference was found between the materials at any levels of 0. 5, 2, and 3. 5 mm (P<0. 01). Conclusion: Blood exposure resulted in the decrease of microHardness of internal part of the materials.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SHOKOUHINEJAD, NOUSHIN, RAZMI, HASSAN, KHOSHKHOUNEJAD, MEHRFAM, & Firouzmanesh, Pegah. (2017). The effect of blood and synthetic tissue fluid on the microhardness of ProRoot MTA, OrthoMTA and RetroMTA. JOURNAL OF DENTAL MEDICINE, 30(3 ), 136-143. SID. https://sid.ir/paper/25715/en

    Vancouver: Copy

    SHOKOUHINEJAD NOUSHIN, RAZMI HASSAN, KHOSHKHOUNEJAD MEHRFAM, Firouzmanesh Pegah. The effect of blood and synthetic tissue fluid on the microhardness of ProRoot MTA, OrthoMTA and RetroMTA. JOURNAL OF DENTAL MEDICINE[Internet]. 2017;30(3 ):136-143. Available from: https://sid.ir/paper/25715/en

    IEEE: Copy

    NOUSHIN SHOKOUHINEJAD, HASSAN RAZMI, MEHRFAM KHOSHKHOUNEJAD, and Pegah Firouzmanesh, “The effect of blood and synthetic tissue fluid on the microhardness of ProRoot MTA, OrthoMTA and RetroMTA,” JOURNAL OF DENTAL MEDICINE, vol. 30, no. 3 , pp. 136–143, 2017, [Online]. Available: https://sid.ir/paper/25715/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top