مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

272
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

327
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INDOOR AIR QUALITY ASSESSMENT IN A RADIANTLY COOLED TROPICAL BUILDING: A CASE STUDY

Pages

  89-93

Keywords

INDOOR AIR QUALITY (IAQ) 

Abstract

 Background: Many studies have been conducted to assess the indoor air quality (IAQ) of buildings throughout the world because it is closely related to comfort, safety and work productivity of occupants. However, there is still lack of available literature about IAQ in tropical buildings that apply RADIANT COOLING SYSTEMS in conditioning the indoor air.Methods: This paper reports the results obtained from an IAQ AUDIT that was conducted in a new radiantly cooled building in Malaysia, by focusing on the IAQ and thermal comfort parameters.Results: It was identified that the measured concentration levels for the five INDOOR AIR CONTAMINANTS (CO, CO2, TVOC, formaldehyde and respirable particulates) were within the threshold limit values (TLVs) specified in the IAQ guidelines. Besides, no significant difference was found between the contaminant levels in each floor of the studied building, and a majority of the respondents did not encounter any form of physical discomfort. There is a risk of CONDENSATION problem, judging from the measured RH level.Conclusion: An increase of airflow rate and more dehumidification work in the studied building can be made to improve IAQ and prevention of CONDENSATION problem. Nevertheless, these schemes should be implemented carefully to avoid occupants’ discomfort. Relocation of workstations was suggested, especially for the lower floors, which had higher occupancy levels.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KWONG, QI JIE, ADAM, NOR MARIAH, CIONITA, TEZARA, RAGHAVAN, VIJAY R., & ABD MALEK, MOHD FAREQ. (2014). INDOOR AIR QUALITY ASSESSMENT IN A RADIANTLY COOLED TROPICAL BUILDING: A CASE STUDY. IRANIAN JOURNAL OF PUBLIC HEALTH, 43(SUPPLEMENT 3), 89-93. SID. https://sid.ir/paper/273323/en

    Vancouver: Copy

    KWONG QI JIE, ADAM NOR MARIAH, CIONITA TEZARA, RAGHAVAN VIJAY R., ABD MALEK MOHD FAREQ. INDOOR AIR QUALITY ASSESSMENT IN A RADIANTLY COOLED TROPICAL BUILDING: A CASE STUDY. IRANIAN JOURNAL OF PUBLIC HEALTH[Internet]. 2014;43(SUPPLEMENT 3):89-93. Available from: https://sid.ir/paper/273323/en

    IEEE: Copy

    QI JIE KWONG, NOR MARIAH ADAM, TEZARA CIONITA, VIJAY R. RAGHAVAN, and MOHD FAREQ ABD MALEK, “INDOOR AIR QUALITY ASSESSMENT IN A RADIANTLY COOLED TROPICAL BUILDING: A CASE STUDY,” IRANIAN JOURNAL OF PUBLIC HEALTH, vol. 43, no. SUPPLEMENT 3, pp. 89–93, 2014, [Online]. Available: https://sid.ir/paper/273323/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button