مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

338
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

158
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

COARCTOPLASTY WITH SELF-EXPANDABLE STENT IMPLANTATION FOR TREATMENT OF COARCTATION OF AORTA IN ADULTS

Pages

  348-353

Abstract

 Background: Balloon ANGIOPLASTY for treatment of coarctation of the aorta in adults, though promising, is sometimes limited by significant residual gradient (>20 mmHg). Few studies have been reported on use of balloon-expandable stents in such a situation. We evaluated the use of SELF-EXPANDABLE STENTs in patients with coarctation of the aorta. Methods: Eight hypertensive patients (age 15 to 27 years) with coarctation of the aorta (n = 6) or RECOARCTATION (n = 2) and peak systolic gradient of >40 mmHg underwent stent implantation. Balloon predilatation was done and self-expandable nitinol aortic stents (Optimed) were implanted in all patients. Results: The mean ± SD peak systolic gradient decreased from a baseline of 55 ± 15 (range: 40 – 75) to 5 ± 2 (range: 3 – 7) mm Hg after ANGIOPLASTY. Nitinol stents were easier to deploy and conformed better to aortic anatomy as compared with balloon-expandable stents. The mean ± SD diameter of the coarcted segment increased from 3 ± 1 mm to 16 ± 2 mm. There were no complications in our series. On 6- to 9-month follow-up, all the implanted stents remained in their original positions and none showed evidence of fracture. Significant improvement in hypertension was seen in 7 out of 8 patients. Conclusion: Stent implantation is safe and effective in treating coarctation of the aorta. Selfexpandable stents were easy to implant, had good adaptation to the wall of the aorta, and in most patients had similar efficacy in reducing coarctation of the aorta as surgical repair.    

Cites

References

  • No record.
  • Cite

    APA: Copy

    HAJI ZEYNALI, A.M., & GHASEMI, M.. (2006). COARCTOPLASTY WITH SELF-EXPANDABLE STENT IMPLANTATION FOR TREATMENT OF COARCTATION OF AORTA IN ADULTS. ARCHIVES OF IRANIAN MEDICINE, 9(4), 348-353. SID. https://sid.ir/paper/280140/en

    Vancouver: Copy

    HAJI ZEYNALI A.M., GHASEMI M.. COARCTOPLASTY WITH SELF-EXPANDABLE STENT IMPLANTATION FOR TREATMENT OF COARCTATION OF AORTA IN ADULTS. ARCHIVES OF IRANIAN MEDICINE[Internet]. 2006;9(4):348-353. Available from: https://sid.ir/paper/280140/en

    IEEE: Copy

    A.M. HAJI ZEYNALI, and M. GHASEMI, “COARCTOPLASTY WITH SELF-EXPANDABLE STENT IMPLANTATION FOR TREATMENT OF COARCTATION OF AORTA IN ADULTS,” ARCHIVES OF IRANIAN MEDICINE, vol. 9, no. 4, pp. 348–353, 2006, [Online]. Available: https://sid.ir/paper/280140/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button