مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

300
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

101
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ULTRASOUND MONITORING OF TEMPERATURE CHANGE DURING INTERSTITIAL LASER THERMOTHERAPY OF LIVER: AN IN VITRO STUDY

Pages

  95-101

Abstract

 Background/objective: In thermal tissue ablation, it is very important to control the increase in the temperature for having an efficient ablation therapy. We conducted this study to determine the efficacy of measuring pixel shift of ULTRASOUND B-MODE IMAGES as a function of change in tissue temperature.Materials and Methods: By fixing some microthermocouples in liver tissues, temperature at different points was monitored invasively in vitro during laser-induced THERMOTHERAPY. According to our results, optimum power and exposure time were determined for ultrasound TEMPERATURE MONITORING. Simultaneously, noninvasive TEMPERATURE MONITORING was performed with ULTRASOUND B-MODE IMAGES. These images were saved on computer from 25oC to 95oC with 10 oC steps. The speed of sound changes with each 10oC temperature change that produce virtual shifts in the scatter positions. Using an image processing method, the pixel shift due to 10 oC temperature change was extracted by motion detection.Results: The cubic regression function between the mean pixel shifts on ULTRASOUND B-MODE IMAGES caused by the change in speed of sound, which in turn was a function of the mean change in temperature, was evaluated. When temperature increased, pixel shift occurs in ultrasound images. The maximum pixel shift was observed between 60 to 70 oC (temperature changes (DT) of 35–45 oC). After 70oC, the local pixel shift due to change in the speed of sound in liver tissue had an irregular decreasing. Pearson correlation coefficient between invasive and non-invasive measurements for 10oC temperature changes was 0.93 and the non-linear function was suitable for monitoring of temperature.Conclusion: Monitoring of changes in temperature based on pixel shifts observed in ULTRASOUND B-MODE IMAGES in interstitial laser THERMOTHERAPY of liver seems a good modality.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    GORJI ARA, T., MOKHTARI DIZAJI, M., & GHAANATI, H.. (2007). ULTRASOUND MONITORING OF TEMPERATURE CHANGE DURING INTERSTITIAL LASER THERMOTHERAPY OF LIVER: AN IN VITRO STUDY. IRANIAN JOURNAL OF RADIOLOGY, 4(2), 95-101. SID. https://sid.ir/paper/283637/en

    Vancouver: Copy

    GORJI ARA T., MOKHTARI DIZAJI M., GHAANATI H.. ULTRASOUND MONITORING OF TEMPERATURE CHANGE DURING INTERSTITIAL LASER THERMOTHERAPY OF LIVER: AN IN VITRO STUDY. IRANIAN JOURNAL OF RADIOLOGY[Internet]. 2007;4(2):95-101. Available from: https://sid.ir/paper/283637/en

    IEEE: Copy

    T. GORJI ARA, M. MOKHTARI DIZAJI, and H. GHAANATI, “ULTRASOUND MONITORING OF TEMPERATURE CHANGE DURING INTERSTITIAL LASER THERMOTHERAPY OF LIVER: AN IN VITRO STUDY,” IRANIAN JOURNAL OF RADIOLOGY, vol. 4, no. 2, pp. 95–101, 2007, [Online]. Available: https://sid.ir/paper/283637/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button