مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

762
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

370
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A COMPARATIVE MONTE CARLO STUDY ON 6MV PHOTON BEAM CHARACTERISTICS OF VARIAN 21EX AND ELEKTA SL-25 LINACS

Pages

  23-30

Abstract

 Background: MONTE CARLO METHOD (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, VARIAN 21EX and ELEKTA SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of VARIAN 21EX and Elekta Sl- 25 linacs were simulated based on manufacturers provided information. Photon energy spectra and absolute absorbed dose values were calculated for field sizes of 10×10 and 20×20 cm2. Also, contamination electron spectra for field size of 20×20 cm2 were scored for both linacs. Results: Our results showed that the relative absorbed dose values and contamination electron spectrum were similar and comparable, but photon fluence and absolute absorbed dose values were 17% and 13% higher for Varian linac respectively for the field size of 10×10 cm2. Conclusion: Despite the differences in head components of two commercial linacs, their relative depth dose values were very close to each other. The absolute dose per incident electron showed some discrepancy, as well. Thus, this study suggests the use of absolute absorbed dose values as an invaluable factor when different linacs head are compared using MONTE CARLO METHOD.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MESBAHI, A., MEHNATI, P., & KESHTKAR, A.. (2007). A COMPARATIVE MONTE CARLO STUDY ON 6MV PHOTON BEAM CHARACTERISTICS OF VARIAN 21EX AND ELEKTA SL-25 LINACS. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 5(1), 23-30. SID. https://sid.ir/paper/286413/en

    Vancouver: Copy

    MESBAHI A., MEHNATI P., KESHTKAR A.. A COMPARATIVE MONTE CARLO STUDY ON 6MV PHOTON BEAM CHARACTERISTICS OF VARIAN 21EX AND ELEKTA SL-25 LINACS. INTERNATIONAL JOURNAL OF RADIATION RESEARCH[Internet]. 2007;5(1):23-30. Available from: https://sid.ir/paper/286413/en

    IEEE: Copy

    A. MESBAHI, P. MEHNATI, and A. KESHTKAR, “A COMPARATIVE MONTE CARLO STUDY ON 6MV PHOTON BEAM CHARACTERISTICS OF VARIAN 21EX AND ELEKTA SL-25 LINACS,” INTERNATIONAL JOURNAL OF RADIATION RESEARCH, vol. 5, no. 1, pp. 23–30, 2007, [Online]. Available: https://sid.ir/paper/286413/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button