مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

37
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

133
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE IMPACT OF DOSE CALCULATION ALGORITHMS FOR PERIPHERAL DOSE DISTRIBUTIONS OF ENHANCED DYNAMIC AND PHYSICAL WEDGES

Pages

  17-24

Abstract

 Background: In radiaon therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. In this study, the two available calculaon algorithms of the Varian Eclipse 8.6 treatment planning system (TPS), the anisotropic analyc algorithm (AAA) and pencil-beam convoluon (PBC) was used to compare measured and calculated peripheral dose distribuon of PHYSICAL WEDGEd (PW) and ENHANCED DYNAMIC WEDGEd fields (EDW).Materials and Methods: Peripheral dose measurements were carried out for 6 and 18 MV photons using a 0.6cc Farmer-type ionizaon chamber in the slab phantom. Measurements were performed using 15o, 30o, 45o and 60o PW and EDW for three different field sizes at dmax and up to a maximum distance of 50 cm beyond the field edges.peripheral dose was further computed using two different algorithms of a TPS. The measured and calculated datas were then compared to find which algorithm calculates peripheral dose distribuon more accurately.Results: Both algorithms from the TPS adequately model the peripheral dose distribuon up to 45 degrees. For large field sizes with 600 EDW, the largest deviaon between calculated and measured dose distribuon is less than 3.5% using the AAA, but can increase up to 9.7% of the distribuon using PBC.Conclusion: The AAA models wedged peripheral dose distribuons more accurately than the PBC does for all studied condions; the difference between the algorithms are more significant for large wedge angles and large field sizes. It must be emphasized that the use of PBC for planning large-field treatments with 600 EDW could lead to inaccuracies of clinical significance.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ACAR, HILAL, YAVAS, G., & YAVAS, C.. (). . , (), -. SID. https://sid.ir/paper/286700/en

    Vancouver: Copy

    ACAR HILAL, YAVAS G., YAVAS C.. . [Internet]. ;():-. Available from: https://sid.ir/paper/286700/en

    IEEE: Copy

    HILAL ACAR, G. YAVAS, and C. YAVAS, “,” , vol. , no. , pp. –, , [Online]. Available: https://sid.ir/paper/286700/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button