مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

356
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

463
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry

Pages

  275-282

Abstract

 Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addi"on, u"liza"on of high-energy linear accelerator (10 MV) can emit some unwanted par"cles (electron contamina"on). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clinac iX 10 MV Photon beam for square small field size (1×1, 2×2, 3×3, 4×4 and 5×5 cm2) using Monte Carlo (MC) simula"on. Materials and Methods: The commissioning process for this linac, has been conducted for field size 6×6, 10×10 and 20×20 cm2 by comparing the measurement and MC simula"on data. Head linac simula"on was performed with BEAMnrc and dose calcula"on with DOSXYZnrc. The phase space (phsp) data from BEAMnrc was analyzed using BEAMDP to get the par"cles informa"on in scoring plane. Results and Discussion: The sca6er angle of par"cles depends on the field size. This factor affects the penumbra width in water phantom. On the other hand, PDD data show that the depth of maximum dose and penumbra width in small field shi: ed correspond with the number of sca6er par"cle. The difference of rela"ve output factor between measurement and MC results were found less than 2%. However, the 2% difference was s"ll acceptable in Photon beam dosimetry. Conclusion: From this simula"on, the electron contamina"on give contribu"on in surface dose of water phantom about 13. 0581% and less than 1% for field size 10×10 cm2 and small field size, respec"vely.

Cites

References

  • No record.
  • Cite

    APA: Copy

    Yani, S., Rhani, M.F., Soh, R.C.X., Haryanto, f., & Arif, i.. (2017). Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 15(3), 275-282. SID. https://sid.ir/paper/286876/en

    Vancouver: Copy

    Yani S., Rhani M.F., Soh R.C.X., Haryanto f., Arif i.. Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry. INTERNATIONAL JOURNAL OF RADIATION RESEARCH[Internet]. 2017;15(3):275-282. Available from: https://sid.ir/paper/286876/en

    IEEE: Copy

    S. Yani, M.F. Rhani, R.C.X. Soh, f. Haryanto, and i. Arif, “Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry,” INTERNATIONAL JOURNAL OF RADIATION RESEARCH, vol. 15, no. 3, pp. 275–282, 2017, [Online]. Available: https://sid.ir/paper/286876/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button