مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

181
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

116
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DOES ROUTINE REPEAT TESTING OF CRITICAL LABORATORY VALUES IMPROVE THEIR ACCURACY?

Pages

  0-0

Abstract

 Background: Routine repeat testing of critical LABORATORY values is very common these days to increase their ACCURACY and to avoid reporting false or infeasible results. We figure that repeat testing of critical LABORATORY values has any benefits or not.Methods: We examined 2233 repeated critical LABORATORY values in 13 different hematology and chemistry tests including: hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin. The absolute difference and the percentage of change between the two tests for each critical value were calculated and then compared with the College of American Pathologists/Clinical LABORATORY Improvement Amendments ALLOWABLE ERROR.Results: Repeat testing yielded results that were within the ALLOWABLE ERROR on 2213 of 2233 specimens (99.1%). There was only one outlier (0.2%) in the white blood cell test category, 9 (2.9%) in the platelet test category, 5 (4%) in the partial thromboplastin time test category, 5 (4.8%) in the international normalized ratio test category and none in other test categories.Conclusion: Routine, repeat testing of critical hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin results does not have any benefits to increase their ACCURACY.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BARADARAN MOTIE, POOYA, ZARE MIRZAIE, ALI, SHAYANFAR, NASRIN, & KADIVAR, MARYAM. (2015). DOES ROUTINE REPEAT TESTING OF CRITICAL LABORATORY VALUES IMPROVE THEIR ACCURACY?. MEDICAL JOURNAL OF THE ISLAMIC REPUBLIC OF IRAN (MJIRI), 29(1), 0-0. SID. https://sid.ir/paper/294658/en

    Vancouver: Copy

    BARADARAN MOTIE POOYA, ZARE MIRZAIE ALI, SHAYANFAR NASRIN, KADIVAR MARYAM. DOES ROUTINE REPEAT TESTING OF CRITICAL LABORATORY VALUES IMPROVE THEIR ACCURACY?. MEDICAL JOURNAL OF THE ISLAMIC REPUBLIC OF IRAN (MJIRI)[Internet]. 2015;29(1):0-0. Available from: https://sid.ir/paper/294658/en

    IEEE: Copy

    POOYA BARADARAN MOTIE, ALI ZARE MIRZAIE, NASRIN SHAYANFAR, and MARYAM KADIVAR, “DOES ROUTINE REPEAT TESTING OF CRITICAL LABORATORY VALUES IMPROVE THEIR ACCURACY?,” MEDICAL JOURNAL OF THE ISLAMIC REPUBLIC OF IRAN (MJIRI), vol. 29, no. 1, pp. 0–0, 2015, [Online]. Available: https://sid.ir/paper/294658/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button