مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

250
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

97
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INTENSE MICROBUBBLES MIMICKING MOBILE THROMBUS IN A PATIENT WITH PROSTHETIC MITRAL VALVE

Pages

  81-83

Abstract

MICROBUBBLEs have been presumed as gaseous emboli, which originate during mechanical heart valve closure, but are not seen in bioprosthetic valves. In this report, we presented a cluster of MICROBUBBLEs mimicking mobile thrombus in a patient with mechanical MITRAL VALVE prosthesis. A 30-year-old female with a history of implanted mechanical valve at the mitral position underwent a routine examination. She was asymptomatic and her physical examination was unremarkable. Transthoracic echocardiography showed a mobile thrombus-like mass on the ventricular side of the prosthetic MITRAL VALVE moving into the left ventricular outflow tract. However, close examination of images indicated that the mass was in fact intense MICROBUBBLEs mimicking thrombus. Intense mobile MICROBUBBLEs can be misdiagnosed as a mobile thrombus. We recommend and underscore the importance of detailed echocardiographic examination in case of mobile mass to avoid misdiagnosis in patients with mechanical heart valves.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    COSKUN, FATMA YILMAZ, OZER, ORHAN, & ALTUNBAS, GOKHAN. (2017). INTENSE MICROBUBBLES MIMICKING MOBILE THROMBUS IN A PATIENT WITH PROSTHETIC MITRAL VALVE. INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 11(2), 81-83. SID. https://sid.ir/paper/314314/en

    Vancouver: Copy

    COSKUN FATMA YILMAZ, OZER ORHAN, ALTUNBAS GOKHAN. INTENSE MICROBUBBLES MIMICKING MOBILE THROMBUS IN A PATIENT WITH PROSTHETIC MITRAL VALVE. INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL[Internet]. 2017;11(2):81-83. Available from: https://sid.ir/paper/314314/en

    IEEE: Copy

    FATMA YILMAZ COSKUN, ORHAN OZER, and GOKHAN ALTUNBAS, “INTENSE MICROBUBBLES MIMICKING MOBILE THROMBUS IN A PATIENT WITH PROSTHETIC MITRAL VALVE,” INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, vol. 11, no. 2, pp. 81–83, 2017, [Online]. Available: https://sid.ir/paper/314314/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button