مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

303
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

146
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE TWELVE-MONTH OUTCOME OF BIOLIMUS ELUTING STENT WITH BIODEGRADABLE POLYMER COMPARED WITH AN EVEROLIMUS ELUTING STENT WITH DURABLE POLYMER

Pages

  117-120

Abstract

 Introduction Drug-eluting stents (DES) have significantly decreased the need for repeat coronary REVASCULARIZATION but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a BIOLIMUS-ELUTING STENT (with BIODEGRADABLE POLYMER) with an everolimus-eluting stent (with durable polymer) one.Methods: We performed a randomized trial to compare the two types of stents. Two hundred patients undergoing PCI for de novo lesions were randomly assigned 1: 1 to treatment with either biolimus-eluting (BioMatrix) or everolimus-eluting (Xience V) stent. The primary endpoint was a composite of cardiac death, myocardial infarction, and clinically driven target vessel REVASCULARIZATION within 12 months.Results: Demographics, clinical, and lesion characteristic were comparable between two groups. The 30-day major adverse cardiac event (MACE) rate was 2% in BioMatrix group versus 0% in Xience group (p>0.05). After 12 months, the rates of cardiac death (0% in both groups), MI (2% versus 0%, p=0.49) and clinically-driven target vessel REVASCULARIZATION (0% in both groups) were similar for BioMatrix and Xience. No stent thrombosis was reported at 1, 6, 9 or 12 months after intervention in either group.Conclusion: BES (BIOLIMUS-ELUTING STENT) with BIODEGRADABLE POLYMER and EES (Everolimus-eluting stent) with durable polymer appear similar with respect to MACE and stent thrombosis in this patient population. Many studies with longer follow up are needed to define better the role of BES with bio-degradable polymer in treatment of coronary artery lesions.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SEPARHAM, AHMAD, SOHRABI, BAHRAM, ASLANABADI, NASER, & GHAFFARI, SAMAD. (2011). THE TWELVE-MONTH OUTCOME OF BIOLIMUS ELUTING STENT WITH BIODEGRADABLE POLYMER COMPARED WITH AN EVEROLIMUS ELUTING STENT WITH DURABLE POLYMER. JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 3(4), 117-120. SID. https://sid.ir/paper/314870/en

    Vancouver: Copy

    SEPARHAM AHMAD, SOHRABI BAHRAM, ASLANABADI NASER, GHAFFARI SAMAD. THE TWELVE-MONTH OUTCOME OF BIOLIMUS ELUTING STENT WITH BIODEGRADABLE POLYMER COMPARED WITH AN EVEROLIMUS ELUTING STENT WITH DURABLE POLYMER. JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH[Internet]. 2011;3(4):117-120. Available from: https://sid.ir/paper/314870/en

    IEEE: Copy

    AHMAD SEPARHAM, BAHRAM SOHRABI, NASER ASLANABADI, and SAMAD GHAFFARI, “THE TWELVE-MONTH OUTCOME OF BIOLIMUS ELUTING STENT WITH BIODEGRADABLE POLYMER COMPARED WITH AN EVEROLIMUS ELUTING STENT WITH DURABLE POLYMER,” JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, vol. 3, no. 4, pp. 117–120, 2011, [Online]. Available: https://sid.ir/paper/314870/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button