مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

146
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

83
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Intra-aortic balloon pump experience: a single center study comparing with and without sheath insertion

Pages

  144-148

Abstract

 Introduction: The mechanical circulation support used in treatment of low cardiac output at most is the Intra-aortic Balloon Pump (IABP). Its usage fields are the complications occurring due to ischemic heart disease, disrupted left ventricle function, and the low cardiac output syndrome occurring during coronary artery by-pass surgery. Methods: During 28 years from 1985 to 2013, IABP support has been implemented to 3135 patients in our cardiac surgery operating theater and intensive care unit. The mean age of the patients was 61. 4 ± 13. 2 years (16-82). 2506 patients (80%) were the ones whom the cardiac surgery has been implemented. IABP support has been provided for 629 (20%) patients for medical treatment. We utilized IABP most frequently in coronary artery patients (70%). The first choice for placing the balloon catheter is the femoral artery in 3093 cases (98. 7%). Results: The most frequently observed balloon complication was the lower extremity ischemia in 383 cases (12. 2%). The leg ischemia was statistically significantly more frequent in patients with sheath (P = 0. 004). The extremity ischemia has developed in 4 of 12 patients with balloon placed from upper extremity. The local bleeding and balloon rupture were more frequent in patients whom the balloon has been placed without sheath. The mortality due to IABP has occurred in only 5 patients. Conclusion: Despite increase in IABP usage frequency rapidly, the complications due to catheter are still seen. We believe that the leg ischemia that is the most frequently seen complication can be prevented via IABP use without sheath.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ozen, Yucel, Aksut, Mehmet, Cekmecelioglu, Davut, DEDEMOGLU, MEHMET, Altas, Ozge, Sarikaya, Sabit, Rabus, Murat Bulent, & Kirali, Kaan. (2018). Intra-aortic balloon pump experience: a single center study comparing with and without sheath insertion. JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 10(3), 144-148. SID. https://sid.ir/paper/314971/en

    Vancouver: Copy

    ozen Yucel, Aksut Mehmet, Cekmecelioglu Davut, DEDEMOGLU MEHMET, Altas Ozge, Sarikaya Sabit, Rabus Murat Bulent, Kirali Kaan. Intra-aortic balloon pump experience: a single center study comparing with and without sheath insertion. JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH[Internet]. 2018;10(3):144-148. Available from: https://sid.ir/paper/314971/en

    IEEE: Copy

    Yucel ozen, Mehmet Aksut, Davut Cekmecelioglu, MEHMET DEDEMOGLU, Ozge Altas, Sabit Sarikaya, Murat Bulent Rabus, and Kaan Kirali, “Intra-aortic balloon pump experience: a single center study comparing with and without sheath insertion,” JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, vol. 10, no. 3, pp. 144–148, 2018, [Online]. Available: https://sid.ir/paper/314971/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button