مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,272
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATING THE EFFECTS OF DUAL FREQUENCY SONICATION PARAMETERS ON ACOUSTIC CAVITATION BY CHEMICAL DOSIMETER USING IODIDE

Pages

  179-192

Abstract

 Background and Aims: Production of ACOUSTIC CAVITATION by sonication has been recently recommended as a targeted treatment. The experimental results from studies indicate that the activity of cavitation generated by bi- or multi-frequency ultrasound irradiation is higher than that caused by single frequency irradiation. In this study, effects dual (1 MHz and 40 kHz) and single frequency sonication on ACOUSTIC CAVITATION were investigated by chemical dosimeter using iodide.Methods: In this study, we investigated the exposure parameters in low level dual-frequency ultrasound in near fields of 40 kHz and 1 MHz in the progressive wave mode by chemical dosimeter using iodide. Finally, the effective protocol for enhancement of the inertial cavitation activity was determined.Results: It has been shown that the dosimeter absorbance in the continuous mode sonication is more than the pulse mode. Moreover, significant correlations were found between the time and intensity of single and DUAL FREQUENCY SONICATION and the iodide dosimeter absorbance. In constant energy, inertial cavitation activity in the pulse mode remained approximately constant. Among different combinations, the combined ultrasound sonication in continuous mode could produce a more remarkable enhancement of the inertial cavitation activity (1.78 times) than the algebraic sum.Conclusion: Simultaneous combined DUAL FREQUENCY SONICATION is more effective than single frequency sonication in producing the inertial cavitation activity.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    EBRAHIMNIA, A., MOKHTARI DIZAJI, M., & TOLIYAT, T.. (2013). EVALUATING THE EFFECTS OF DUAL FREQUENCY SONICATION PARAMETERS ON ACOUSTIC CAVITATION BY CHEMICAL DOSIMETER USING IODIDE. JOURNAL OF KERMAN UNIVERSITY OF MEDICAL SCIENCES, 20(2), 179-192. SID. https://sid.ir/paper/318/en

    Vancouver: Copy

    EBRAHIMNIA A., MOKHTARI DIZAJI M., TOLIYAT T.. EVALUATING THE EFFECTS OF DUAL FREQUENCY SONICATION PARAMETERS ON ACOUSTIC CAVITATION BY CHEMICAL DOSIMETER USING IODIDE. JOURNAL OF KERMAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2013;20(2):179-192. Available from: https://sid.ir/paper/318/en

    IEEE: Copy

    A. EBRAHIMNIA, M. MOKHTARI DIZAJI, and T. TOLIYAT, “EVALUATING THE EFFECTS OF DUAL FREQUENCY SONICATION PARAMETERS ON ACOUSTIC CAVITATION BY CHEMICAL DOSIMETER USING IODIDE,” JOURNAL OF KERMAN UNIVERSITY OF MEDICAL SCIENCES, vol. 20, no. 2, pp. 179–192, 2013, [Online]. Available: https://sid.ir/paper/318/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top