مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

547
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

159
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

PERFORMANCE CHARACTERISTICS OF THREE AUTOMATED IMMUNOASSAYS FOR THYROID HORMONES

Pages

  400-404

Abstract

 Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of IMMUNOASSAYs such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent IMMUNOASSAY (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 IMMUNOASSAY system and compared the results of this method with those of radioimmunoassay (RIA) [immunoradiometric (IRMA) for TSH] and Elisa.Methods: Fasting serum from 112 hypo, hyper and euthyroid patients were used to evaluate the minimum detectable concentration, intra- and inter-assay precisions for TSH, FT4, T3, linearity for TSH assay and method comparison study.Results: Within the analytical range tested, intra-assay coefficient of variation was <2.3% for TSH, 2.3% for FT4 and 7.8% for T3. The inter-assay coefficient of variation was < 2.9% for TSH, 2.5% for FT4 and 12.3% for T3. The measurement of diluted sera indicated a desirable percentage of recovery for TSH. No correlation was found between Elecsys 2010 and Elisa /IRMA for TSH. The comparison of results of the Elecsys ECLIA assay with those of Elisa and RIA for T4 were: T4 (ECLIA) =-0.612+0.999, T4 (Elisa, r=0.88) and T4 (ECLIA)=0.642+0.942 T4 (RIA, r=0.957), while ECLIA assay with Elisa and RIA for T3 were: T3 (ECLIA)=0.242+0.908 T3 (Elisa, r=0.8) and T3 (ECLIA) =-0.029+1.01 T3 (RIA, r=0.957).Conclusion: The results show that Elecsys 2010 is an automated reliable, efficient and technically excellent instrument to use in the measurement of serum TSH, T4 and T3.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KAZEROUNI, FARANAK, & AMIRRASOULI, HOUSHANG. (2012). PERFORMANCE CHARACTERISTICS OF THREE AUTOMATED IMMUNOASSAYS FOR THYROID HORMONES. CASPIAN JOURNAL OF INTERNAL MEDICINE, 3(2 (10)), 400-404. SID. https://sid.ir/paper/323244/en

    Vancouver: Copy

    KAZEROUNI FARANAK, AMIRRASOULI HOUSHANG. PERFORMANCE CHARACTERISTICS OF THREE AUTOMATED IMMUNOASSAYS FOR THYROID HORMONES. CASPIAN JOURNAL OF INTERNAL MEDICINE[Internet]. 2012;3(2 (10)):400-404. Available from: https://sid.ir/paper/323244/en

    IEEE: Copy

    FARANAK KAZEROUNI, and HOUSHANG AMIRRASOULI, “PERFORMANCE CHARACTERISTICS OF THREE AUTOMATED IMMUNOASSAYS FOR THYROID HORMONES,” CASPIAN JOURNAL OF INTERNAL MEDICINE, vol. 3, no. 2 (10), pp. 400–404, 2012, [Online]. Available: https://sid.ir/paper/323244/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top