Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

254
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

USE OF TWO ENDOTRACHEAL TUBES TO PERFORM LUNG ISOLATION AND ONE-LUNG VENTILATION IN A PATIENT WITH TRACHEOSTOMY STENOSIS: A CASE REPORT

Pages

  0-0

Abstract

 Introduction: LUNG ISOLATION is a common technique used in thoracic surgery to prevent spillage to unaffected lung and to provide a better view for the surgeon.Case Presentation: A 41-year-old woman with a history of pharyngo-laryngo-oesophagectomy (PLO) and TRACHEOSTOMY was a candidate for thoracic duct ligation because of chylothorax. Since the patient had tracheostmy stomal stenosis, two cuffed tracheal tubes (internal diameter=4.5 mm) were used; one tube was placed in the right bronchus and the other tube in the left one by fiberoptic laryngoscopy in 10 minutes. Right lung was collapsed during the surgery for 3.5 hours with a slight decrease in oxygenation (SpO2=91%–93%) and with no evident hemodynamic change. Potential trauma from a double-lumen tube and a bronchial blocker as well as inaccessibility to a univent tube prevented us to use these standard methods in this case.Conclusions: This report presents a new method for LUNG ISOLATION in specific cases and in the absence of certain equipment.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    TAGHAVI GILANI, MEHRYAR, FATHI, MEHDI, & RAZAVI, MAJID. (2014). USE OF TWO ENDOTRACHEAL TUBES TO PERFORM LUNG ISOLATION AND ONE-LUNG VENTILATION IN A PATIENT WITH TRACHEOSTOMY STENOSIS: A CASE REPORT. ANESTHESIOLOGY AND PAIN MEDICINE, 4(4), 0-0. SID. https://sid.ir/paper/328475/en

    Vancouver: Copy

    TAGHAVI GILANI MEHRYAR, FATHI MEHDI, RAZAVI MAJID. USE OF TWO ENDOTRACHEAL TUBES TO PERFORM LUNG ISOLATION AND ONE-LUNG VENTILATION IN A PATIENT WITH TRACHEOSTOMY STENOSIS: A CASE REPORT. ANESTHESIOLOGY AND PAIN MEDICINE[Internet]. 2014;4(4):0-0. Available from: https://sid.ir/paper/328475/en

    IEEE: Copy

    MEHRYAR TAGHAVI GILANI, MEHDI FATHI, and MAJID RAZAVI, “USE OF TWO ENDOTRACHEAL TUBES TO PERFORM LUNG ISOLATION AND ONE-LUNG VENTILATION IN A PATIENT WITH TRACHEOSTOMY STENOSIS: A CASE REPORT,” ANESTHESIOLOGY AND PAIN MEDICINE, vol. 4, no. 4, pp. 0–0, 2014, [Online]. Available: https://sid.ir/paper/328475/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    مرکز اطلاعات علمی SID
    strs
    دانشگاه امام حسین
    بنیاد ملی بازیهای رایانه ای
    کلید پژوه
    ایران سرچ
    ایران سرچ
    File Not Exists.
    Move to top