Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

140
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

75
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Three Dimensional Quality Assessments of Applied Pelvic Binders

Pages

  156-161

Abstract

 Objective: To assess the quality of applied Pelvic binders using three dimensional computer tomography (3D CT). Methods: A local trauma registry was used to identify patients with pelvic fractures after high-energy trauma during 2011-2015. A 3D CT reconstruction was made from the initial trauma computer tomography images to assess the level of application, symmetricity of the binder and achieved fracture reduction. An acceptable application of the Pelvic binder was deemed if it was at the trochanteric level, symmetric and minimized residual displacement. Results: We found 73 patients with a pelvic fracture and a Pelvic binder on the initial trauma CT-scan. The mean (± SD) age of the patients was 46± 17 years and 40% (n=29) were females. The median ISS score was 38 (IQR; 29-50), the mean systolic blood pressure on arrival was 106± 46 mmHg and the median GCS on arrival was 14 (IQR; 7-15). We found that 59% (n=43) of the binders were correctly applied (symmetric at the trochanteric level, symmetrical and with acceptable residual displacement of the fracture). The 30-day mortality was higher in patients with non-correct application 17% (n=5/30) compared to patients with correct application of the Pelvic binder 9. 3% (n=4/43) however this was not statistically significant (p=0. 562). Conclusion: A substantial number of patients had non-correct application of Pelvic binders. Future studies using 3D technique are encouraged to further investigate clinical impacts of non-appropriate application of Pelvic binders.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    Bakhshayesh, Peyman, Risling, David Hullberg, & Enocson, Anders. (2019). Three Dimensional Quality Assessments of Applied Pelvic Binders. BULLETIN OF EMERGENCY AND TRAUMA BEAT, 7(2), 156-161. SID. https://sid.ir/paper/335227/en

    Vancouver: Copy

    Bakhshayesh Peyman, Risling David Hullberg, Enocson Anders. Three Dimensional Quality Assessments of Applied Pelvic Binders. BULLETIN OF EMERGENCY AND TRAUMA BEAT[Internet]. 2019;7(2):156-161. Available from: https://sid.ir/paper/335227/en

    IEEE: Copy

    Peyman Bakhshayesh, David Hullberg Risling, and Anders Enocson, “Three Dimensional Quality Assessments of Applied Pelvic Binders,” BULLETIN OF EMERGENCY AND TRAUMA BEAT, vol. 7, no. 2, pp. 156–161, 2019, [Online]. Available: https://sid.ir/paper/335227/en