مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

262
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

111
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Pages

  4771-4782

Keywords

Film to focus distance (FFD) 

Abstract

 Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether increasing the FFD from 100 to 130 cm is equally effective for other common radiological procedures and performing a literature review of published studies to address the feasibility and probable limitations against implementing this optimization tool in clinical practice. Materials and Methods Radiographic examination of the pelvis (AP view), abdomen (AP view), skull (AP and lateral view), and spine (AP and lateral view), were taken of pediatric patients. The radiation dose and Image quality of a radiological procedure is measured in FFD of 100 cm (reference FFD) and 130 cm (increased FFD). The thermo-luminescent dosimeters (TLD) were used for radiation dose measurements and visual grading analysis (VGA) for Image quality assessments. Results: Statistically significant reduction in the ESD ranged from 21. 91% for the lateral skull projection to 35. 24% for the lateral spine projection was obtained, when the FFD was increased from 100 to 130 cm (P<0. 05). Optimum Image quality was obtained for all projections in both FFDs. VGA of the resultant images demonstrated a statistically non-significant minor increase in Image quality of lateral skull and spine projections, when increasing from 100 to 130 cm FFDs (P>0. 05). Conclusion Increasing the FFD from 100 to 130 cm has significantly reduced radiation exposure without affecting on Image quality. Our findings are commensurate with the literatures and emphasized that radiographers should learn to use of an updated reference FFD of 130 cm in clinical practice.

Cites

References

  • No record.
  • Cite

    APA: Copy

    KARAMI, VAHID, ZABIHZADEH, MANSOUR, SHAMS, NASIM, & GILAVAND, ABDOLREZA. (2017). Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD). INTERNATIONAL JOURNAL OF PEDIATRICS, 5(4 (40)), 4771-4782. SID. https://sid.ir/paper/337511/en

    Vancouver: Copy

    KARAMI VAHID, ZABIHZADEH MANSOUR, SHAMS NASIM, GILAVAND ABDOLREZA. Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD). INTERNATIONAL JOURNAL OF PEDIATRICS[Internet]. 2017;5(4 (40)):4771-4782. Available from: https://sid.ir/paper/337511/en

    IEEE: Copy

    VAHID KARAMI, MANSOUR ZABIHZADEH, NASIM SHAMS, and ABDOLREZA GILAVAND, “Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD),” INTERNATIONAL JOURNAL OF PEDIATRICS, vol. 5, no. 4 (40), pp. 4771–4782, 2017, [Online]. Available: https://sid.ir/paper/337511/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button