مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

224
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

113
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

IQ-CPR Meter for Chest Compression Monitoring During Simulated Cardiopulmonary Resuscitation; a Comparative Study

Pages

  0-0

Abstract

 Introduction: Adequate chest compression is crucial for cardiopulmonary resuscitation (CPR). There are several chest compression monitoring devices with different costs. This study aimed to evaluate the agreement rate of Improved Quality of cardiopulmonary resuscitation meter (IQ-CPR meter) and automated external defibrillator (AED) in chest compression quality monitoring. Methods: In this comparative study, participants were instructed to perform chest compression on the CPR manikins with the set rate of 110 times/minute for two minutes. The CPR manikins had two monitors: AED (R series® , Zoll company) and IQ-CPR meter. AED showed the depth and speed of chest compression on the screen, while IQ-CPRmeter showed the depth of each chest compression by color light for quality of chest compression depth. Video-based analysis was used to compare the chest compression quality monitoring between the 2 devices. Results: There were 27 participants in the study with a mean age and body mass index (standard deviation; SD) of 26. 00 (5. 65) years, and 22. 93 (3. 62) kg/m2 (70. 37% male). The median (1s t to 3r d quartile range) of chest compression experience was 3 (1. 00-6. 50) years. The mean (SD) of chest compression rate was 107 (5. 29) times/minute. Based on Cohen’ s Kappa correlation, agreement between the IQ-CPR meter and the AED was 66. 54%. Conclusion: The IQ-CPR meter had fair agreement with the computerized chest compression monitoring device with lower cost and simple, real time audiovisual feedback.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    Phattharapornjaroen, Phatthranit, Surapornpaiboon, Suwitchaya, Chalermdamrichai, Phanorn, Sittichanbuncha, Yuwares, & SAWANYAWISUTH, KITTISAK. (2020). IQ-CPR Meter for Chest Compression Monitoring During Simulated Cardiopulmonary Resuscitation; a Comparative Study. ARCHIVES OF ACADEMIC EMERGENCY MEDICINE (EMERGENCY), 8(1), 0-0. SID. https://sid.ir/paper/339910/en

    Vancouver: Copy

    Phattharapornjaroen Phatthranit, Surapornpaiboon Suwitchaya, Chalermdamrichai Phanorn, Sittichanbuncha Yuwares, SAWANYAWISUTH KITTISAK. IQ-CPR Meter for Chest Compression Monitoring During Simulated Cardiopulmonary Resuscitation; a Comparative Study. ARCHIVES OF ACADEMIC EMERGENCY MEDICINE (EMERGENCY)[Internet]. 2020;8(1):0-0. Available from: https://sid.ir/paper/339910/en

    IEEE: Copy

    Phatthranit Phattharapornjaroen, Suwitchaya Surapornpaiboon, Phanorn Chalermdamrichai, Yuwares Sittichanbuncha, and KITTISAK SAWANYAWISUTH, “IQ-CPR Meter for Chest Compression Monitoring During Simulated Cardiopulmonary Resuscitation; a Comparative Study,” ARCHIVES OF ACADEMIC EMERGENCY MEDICINE (EMERGENCY), vol. 8, no. 1, pp. 0–0, 2020, [Online]. Available: https://sid.ir/paper/339910/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button