مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

343
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

130
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ELECTROCHEMICAL EVALUATION OF HYDROXYAPATITE/ZRN COATED MAGNESIUM BIODEGRADABLE ALLOY IN RINGER SOLUTION AS A SIMULATED BODY FLUID

Pages

  45-53

Abstract

 Magnesium alloys as biodegradable materials can be used in body as an implant materials but since they have poor CORROSION resistance, it is required to decrease their CORROSION rate by biocompatible coatings. In this study, HYDROXYAPATITE (HA) coatings in the presence of an intermediate layer of ZrN as a biocompatible material, deposited on AZ91 magnesium alloy by ion beam SPUTTERING method at 300 oC temperature and at different times 180, 240, 300, 360 and 420 min. Then changes in CORROSION resistance of samples in Ringer's solution as a solution similar to the human body was evaluated in two ways, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). To investigate the causes of the destruction of the samples, the surface of samples was studied by scanning electron microscopy (SEM). The results showed that because of porous coatings created, the CORROSION potential of the samples was about +55mV higher than the uncoated substrate that by changing the deposition time, was not observed the significant change But with increasing deposition time to 360 min, CORROSION current decreased which represents an increase of CORROSION resistance of magnesium alloy in body solution. However, a further increase in deposition time to 420 min, due to increase thickness and stress in the layer, the CORROSION resistance of the samples was reduced. The results of the EIS confirm the CORROSION behavior of the polarization method, too.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KIAHOSSEINI, SEYED RAHIM, AFSHAR, ABDOLLAH, MOJTAHEDZADEH LARIJANI, MAJID, & YOUSEFPOUR, MARDALI. (2015). ELECTROCHEMICAL EVALUATION OF HYDROXYAPATITE/ZRN COATED MAGNESIUM BIODEGRADABLE ALLOY IN RINGER SOLUTION AS A SIMULATED BODY FLUID. JOURNAL OF CHEMICAL HEALTH RISKS (JCHR), 5(1), 45-53. SID. https://sid.ir/paper/340253/en

    Vancouver: Copy

    KIAHOSSEINI SEYED RAHIM, AFSHAR ABDOLLAH, MOJTAHEDZADEH LARIJANI MAJID, YOUSEFPOUR MARDALI. ELECTROCHEMICAL EVALUATION OF HYDROXYAPATITE/ZRN COATED MAGNESIUM BIODEGRADABLE ALLOY IN RINGER SOLUTION AS A SIMULATED BODY FLUID. JOURNAL OF CHEMICAL HEALTH RISKS (JCHR)[Internet]. 2015;5(1):45-53. Available from: https://sid.ir/paper/340253/en

    IEEE: Copy

    SEYED RAHIM KIAHOSSEINI, ABDOLLAH AFSHAR, MAJID MOJTAHEDZADEH LARIJANI, and MARDALI YOUSEFPOUR, “ELECTROCHEMICAL EVALUATION OF HYDROXYAPATITE/ZRN COATED MAGNESIUM BIODEGRADABLE ALLOY IN RINGER SOLUTION AS A SIMULATED BODY FLUID,” JOURNAL OF CHEMICAL HEALTH RISKS (JCHR), vol. 5, no. 1, pp. 45–53, 2015, [Online]. Available: https://sid.ir/paper/340253/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button