مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

686
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A comparison of the heart rate deflection point by the S. Dmax method and the ventilatory threshold in sedentary men

Pages

  129-138

Abstract

 Purpose: The aim of this study was to survey of the relationship between Heart rate deflection point (HRDP) by the short distance maximum (S. Dmax) and Second ventilatory threshold (VT2). Methods: Twenty-one sedentary men volunteers (mean age 19. 9± 1. 31 years; height 173. 4± 5. 3 cm; weight 67. 9± 8. 9 kg; maximum oxygen uptake 3. 08± 0. 52 L. min-1) performed an incremental treadmill exercise test to exhaustion. To determine the HRDP, each subject heart rate was recorded by using a polar monitor and analyzed by a designed computer program. Respiratory gases during the exercise test was measured with a gas analyzing system. Data were analyzed using depended t-test, Bland and Altman plots and intraclass correlation coefficient. Results: The HRDP was noticed in all subjects. No significant difference (p > 0. 05) between the heart rate, oxygen uptake, ventilation, tidal volume and respiratory rate corresponding to HRDP and VT2. Also, results of ICC and Bland-Altman plots showed a good agreement between HR and VO2 measured at the HRDP and VT2. Conclusions: It could be concluded that S. Dmax method is an accurate and reliable alternative to the expensive and time-consuming invasive methods. Therefore, the S. Dmax method can be used for the determination of Anaerobic threshold in healthy young men.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    esbarzadeh, Mehdi, SIAHKOUHIAN, MAREFAT, & BOLBOLI, LOTFALI. (2018). A comparison of the heart rate deflection point by the S. Dmax method and the ventilatory threshold in sedentary men. PHYSIOLOGY OF SPORT AND PHYSICAL ACTIVITY, 11(1 ), 129-138. SID. https://sid.ir/paper/375311/en

    Vancouver: Copy

    esbarzadeh Mehdi, SIAHKOUHIAN MAREFAT, BOLBOLI LOTFALI. A comparison of the heart rate deflection point by the S. Dmax method and the ventilatory threshold in sedentary men. PHYSIOLOGY OF SPORT AND PHYSICAL ACTIVITY[Internet]. 2018;11(1 ):129-138. Available from: https://sid.ir/paper/375311/en

    IEEE: Copy

    Mehdi esbarzadeh, MAREFAT SIAHKOUHIAN, and LOTFALI BOLBOLI, “A comparison of the heart rate deflection point by the S. Dmax method and the ventilatory threshold in sedentary men,” PHYSIOLOGY OF SPORT AND PHYSICAL ACTIVITY, vol. 11, no. 1 , pp. 129–138, 2018, [Online]. Available: https://sid.ir/paper/375311/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top