مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

802
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INVESTIGATION OF THE ANISOTROPY CAUSED BY A CYLINDER APPLICATOR ON DOSE DISTRIBUTION AROUND CS-137 BRACHYTHERAPY SOURCES USING THE MCNP4C CODE

Pages

  45-53

Abstract

 Introduction: BRACHYTHERAPY is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix.Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) BRACHYTHERAPY source used in a remote after loading system for treatment of different cancers. This system uses active and inactive spherical sources of 2.5 mm diameter, which can be used in different configurations inside the APPLICATOR to obtain different DOSE DISTRIBUTIONs. In this study, first the DOSE DISTRIBUTION at different distances from the source was obtained around a single pellet inside the APPLICATOR in a water phantom using the MCNP4C Monte Carlo code. The simulations were then repeated for six active pellets in the APPLICATOR and for six point sources.Results: The ANISOTROPY of DOSE DISTRIBUTION due to the presence of the APPLICATOR was obtained by division of dose at each distance and angle to the dose at the same distance and angle of 90 degrees. According to the results, the doses decreased towards the APPLICATOR tips. For example, for points at the distances of 5 and 7 cm from the source and angle of 165 degrees, such discrepancies reached 5.8% and 5.1%, respectively. By increasing the number of pellets to six, these values reached 30% for the angle of 5 degrees.Discussion and Conclusion: The results indicate that the presence of the APPLICATOR causes a significant dose decrease at the tip of the APPLICATOR compared with the dose in the transverse plane. However, the TREATMENT PLANNING systems consider an isotropic DOSE DISTRIBUTION around the source and this causes significant errors in TREATMENT PLANNING, which are not negligible, especially for a large number of sources inside the APPLICATOR.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SINA, SEDIGHEH, FAGHIHI, REZA, ZEHTABIAN, MEHDI, & MEHDIZADEH, SIMIN. (2011). INVESTIGATION OF THE ANISOTROPY CAUSED BY A CYLINDER APPLICATOR ON DOSE DISTRIBUTION AROUND CS-137 BRACHYTHERAPY SOURCES USING THE MCNP4C CODE. IRANIAN JOURNAL OF MEDICAL PHYSICS, 8(2 (31)), 45-53. SID. https://sid.ir/paper/379031/en

    Vancouver: Copy

    SINA SEDIGHEH, FAGHIHI REZA, ZEHTABIAN MEHDI, MEHDIZADEH SIMIN. INVESTIGATION OF THE ANISOTROPY CAUSED BY A CYLINDER APPLICATOR ON DOSE DISTRIBUTION AROUND CS-137 BRACHYTHERAPY SOURCES USING THE MCNP4C CODE. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2011;8(2 (31)):45-53. Available from: https://sid.ir/paper/379031/en

    IEEE: Copy

    SEDIGHEH SINA, REZA FAGHIHI, MEHDI ZEHTABIAN, and SIMIN MEHDIZADEH, “INVESTIGATION OF THE ANISOTROPY CAUSED BY A CYLINDER APPLICATOR ON DOSE DISTRIBUTION AROUND CS-137 BRACHYTHERAPY SOURCES USING THE MCNP4C CODE,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 8, no. 2 (31), pp. 45–53, 2011, [Online]. Available: https://sid.ir/paper/379031/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top