مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,171
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Comparing the precision of pulse oximetry with finger sensor at finger and ear among Vasopressor-treated patients

Pages

  9-18

Abstract

 Background and aims: Nowadays, Finger pulse oximetry has been used for continuous monitoring of oxygen saturation. However, Finger pulse oximetry cannot be always applied on fingertips. In such condition, the same sensor of Finger pulse oximetry on the ear could be applied for reading the oxygen saturation. Regarding the difference of ear and finger tissues and the fact that finger pulse oximeter has been designed for the finger structure; So, the present study was aimed to determine the precision of finger pulse oximeter when used at finger and ear among the patients who were under Vasopressor treatment. Methods: In this comparative descriptive-analytical study, 33 Vasopressor-treated patients in the intense care ward of Kashmar hospital were were selected based on simple and convenience and entered into the study according to inclusion criteria in 2016. Two Finger pulse oximetry sensors were used; one was attached to the fingertip and the other on upper part of auricle. They simultaneously sampled arterial blood. The obtained data were analyzed by SPSS software through Spearman correlation and variance analysis tests on observation replicas. Results: The findings showed that there is a statistically significant difference between SpO2 of the ear (94. 03± 3. 79), fingertip (86. 81± 4. 82) and SaO2 (90. 88± 3. 65) in the Vasopressor-treated patients (P<0. 001). Also, there is a statistically significant relationship between oxygen saturation percent and the time of capillary refill. Conclusion: The results of this study demonstrated that in Vasopressor-treated patients, application of Finger pulse oximetry on ear would lead to results that are more accurate on oxygen saturation as compared to its application on fingertip.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Shaban, M.J., MOHAMMADPOUR, A., KIANMEHR, M., & BALOOCHI BEYDOKHTI, T.. (2018). Comparing the precision of pulse oximetry with finger sensor at finger and ear among Vasopressor-treated patients. JOURNAL OF MULTIDISCIPLINARY CARE (JOURNAL OF CLINICAL NURSING AND MIDWIFERY), 7(1 ), 9-18. SID. https://sid.ir/paper/383487/en

    Vancouver: Copy

    Shaban M.J., MOHAMMADPOUR A., KIANMEHR M., BALOOCHI BEYDOKHTI T.. Comparing the precision of pulse oximetry with finger sensor at finger and ear among Vasopressor-treated patients. JOURNAL OF MULTIDISCIPLINARY CARE (JOURNAL OF CLINICAL NURSING AND MIDWIFERY)[Internet]. 2018;7(1 ):9-18. Available from: https://sid.ir/paper/383487/en

    IEEE: Copy

    M.J. Shaban, A. MOHAMMADPOUR, M. KIANMEHR, and T. BALOOCHI BEYDOKHTI, “Comparing the precision of pulse oximetry with finger sensor at finger and ear among Vasopressor-treated patients,” JOURNAL OF MULTIDISCIPLINARY CARE (JOURNAL OF CLINICAL NURSING AND MIDWIFERY), vol. 7, no. 1 , pp. 9–18, 2018, [Online]. Available: https://sid.ir/paper/383487/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top