مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

15,419
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DIAGNOSTIC ACCURACY OF HEPATIC ARTERY AND PORTAL VEIN DOPPLER ULTRASONOGRAPHY IN CIRRHOTIC PATIENTS

Pages

  95-101

Abstract

 Background: CIRRHOSIS and portal hypertension influence the hepatic circulation. The purpose of this study was to evaluate the diagnostic accuracy of liver DOPPLER ULTRASONOGRAPHY parameters in CIRRHOSIS.Methods: This case-control study involved 118 subjects. All case subjects had biopsyproven hepatic CIRRHOSIS. The controls were healthy people, case-matched for age and gender. All cases and controls underwent Doppler ultrasonographic evaluation. We compared the area under the ROC curve of each parameter for cases vs. controls using Fisher’s exact test, with p <0.5 indicating significance.Results: The means of the following parameters for case vs. control subjects were: frequency of portal venous flow inversion, PORTAL VEIN diameter 12.67±2.72 vs. 10.59±1.69, and hepatic arterial resistance index 0.81±0.07 vs. 0.74±0.09. The mean HEPATIC ARTERY pulsatility index (1.87±0.48 vs. 1.34±0.23), was significantly higher among the case subjects (P=0.001). The maximum flow rate of the PORTAL VEIN was also significantly lower in the case subjects (16.50±5.59 vs. 36.74±8.74 cm/s, P=0.001). We did not observe significant differences in the means of the HEPATIC ARTERY maximum flow rate and end-diastolic flow rate. For diagnosing CIRRHOSIS, the application of 24.1 cm/s as the cutoff point for the PORTAL VEIN maximum flow rate, we obtain an accuracy of 95.45% (91.23%-97.70%, CI=95%), whereas a cutoff point of 1.54 or more for the HEPATIC ARTERY pulsatility index yields an accuracy of 85.71% (79.48%-90.29%, CI=95%). Utilizing a hepatic arterial resistance index of 0.765 or greater is associated with an accuracy of 71.05% (62.81%-78.11%, CI=95%) in diagnosing CIRRHOSIS.Conclusions: DOPPLER ULTRASONOGRAPHY and assessment of HEPATIC ARTERY and PORTAL VEIN parameters are accurate methods in the diagnosis of CIRRHOSIS.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ROKNI YAZDI, H., & SHIR MOHAMMADI, M.. (2008). DIAGNOSTIC ACCURACY OF HEPATIC ARTERY AND PORTAL VEIN DOPPLER ULTRASONOGRAPHY IN CIRRHOTIC PATIENTS. TEHRAN UNIVERSITY MEDICAL JOURNAL (TUMJ), 66(2), 95-101. SID. https://sid.ir/paper/38863/en

    Vancouver: Copy

    ROKNI YAZDI H., SHIR MOHAMMADI M.. DIAGNOSTIC ACCURACY OF HEPATIC ARTERY AND PORTAL VEIN DOPPLER ULTRASONOGRAPHY IN CIRRHOTIC PATIENTS. TEHRAN UNIVERSITY MEDICAL JOURNAL (TUMJ)[Internet]. 2008;66(2):95-101. Available from: https://sid.ir/paper/38863/en

    IEEE: Copy

    H. ROKNI YAZDI, and M. SHIR MOHAMMADI, “DIAGNOSTIC ACCURACY OF HEPATIC ARTERY AND PORTAL VEIN DOPPLER ULTRASONOGRAPHY IN CIRRHOTIC PATIENTS,” TEHRAN UNIVERSITY MEDICAL JOURNAL (TUMJ), vol. 66, no. 2, pp. 95–101, 2008, [Online]. Available: https://sid.ir/paper/38863/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button