مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

3,232
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF BLOOD LOSS IN SEPTORHINOPLASTY WITH TWO DIFFERENT ANESTHETIC TECHNIQUE, PROPOFOL OR ISOFLURANE

Pages

  1-8

Abstract

 Background: Bleeding during nasal operations is a determinant factor in surgical outcome, thus any method that could decrease BLOOD LOSS during this surgery will be valuable. So this study was conducted to compare the amount of BLOOD LOSS in SEPTORHINOPLASTY with two different anesthetic technique, PROPOFOL or ISOFLURANE.Methods: In this prospective randomized clinical trial, 60 patients with ASA physical class I & II, scheduled for SEPTORHINOPLASTY were studied. Patients were randomly allocated into two groups (30 patients in each group). After similar induction of anesthesia in all patients, in Group I, PROPOFOL with remifentanil, and in Group II, ISOFLURANE with remifentanil used for maintenance of anesthesia. The bleeding, surgeons' satisfaction from surgical field and also hemodynamic parameters was noted and compared with SPSS statistical software between two groups across the study.Results: The demographic parameters, surgical and anesthesia related factors were similar in both groups. The mean BLOOD LOSS volume was less in PROPOFOL group (35.3±18.8 ml) than ISOFLURANE (91±18.3 ml) group significantly (p 0.001 Surgeon satisfaction was higher in PROPOFOL group too (p<0.01). Hemodynamic parameters such as heart rate, systolic and diastolic blood pressure and SPO2 were comparable between two groups (except in a few short intervals).Conclusion: It may be concluded that anesthesia with PROPOFOL (TIVA) may result in decreased BLOOD LOSS and higher surgeons satisfaction in SEPTORHINOPLASTY compared with ISOFLURANE anesthesia.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    GHODRATI, MOHAMMADREZA, & ZADIMANI, ALIREZA. (2011). COMPARISON OF BLOOD LOSS IN SEPTORHINOPLASTY WITH TWO DIFFERENT ANESTHETIC TECHNIQUE, PROPOFOL OR ISOFLURANE. JOURNAL OF ANESTHESIOLOGY AND PAIN (PERSIAN), 2(5), 1-8. SID. https://sid.ir/paper/393268/en

    Vancouver: Copy

    GHODRATI MOHAMMADREZA, ZADIMANI ALIREZA. COMPARISON OF BLOOD LOSS IN SEPTORHINOPLASTY WITH TWO DIFFERENT ANESTHETIC TECHNIQUE, PROPOFOL OR ISOFLURANE. JOURNAL OF ANESTHESIOLOGY AND PAIN (PERSIAN)[Internet]. 2011;2(5):1-8. Available from: https://sid.ir/paper/393268/en

    IEEE: Copy

    MOHAMMADREZA GHODRATI, and ALIREZA ZADIMANI, “COMPARISON OF BLOOD LOSS IN SEPTORHINOPLASTY WITH TWO DIFFERENT ANESTHETIC TECHNIQUE, PROPOFOL OR ISOFLURANE,” JOURNAL OF ANESTHESIOLOGY AND PAIN (PERSIAN), vol. 2, no. 5, pp. 1–8, 2011, [Online]. Available: https://sid.ir/paper/393268/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top