مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

2,024
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

EVALUATION OF HEMODIALYSIS ADEQUENCY ON PATIENTS UNDERGOING HEMODIALYSIS IN RAZI HOSPITAL IN RASHT

Pages

  44-49

Abstract

 Introduction: HEMODIALYSIS is the most common replacement therapy for patients with ESRD in Iran. By effective and adequate HEMODIALYSIS can improve life quality and reduced complications of renal failure, inadequate DIALYSIS may lead to some irreversible consequences of uremia. Urea reducation ratio and Kt/v are methods for assessing of DIALYSIS adequacy. Regular assessing of DIALYSIS adequacy is necessary in a HEMODIALYSIS center is necessary but this procedure is not performed regularly in some centers.Objective: evaluation of HEMODIALYSIS adequacy on patients undergoing HEMODIALYSIS in Rasht.Materials and Methods: This is a cross sectional descriptive study. The number of cases was 139, who were selected base on their age, sex, time of DIALYSIS onset, duration of each session and frequency of DIALYSIS in week. They were tested twice, first; before starting the DIALYSIS for BUN, Cr, Alb, Ca, P and Hb, then after ending, for BUN, Cr. The Kt/v was calculated by Daugirdas II formula. Data were analyzed with SPPS Ver10 statistical software and statistical test including c2, t-test and logistic regression. Results: In this study, the mean age of patients was 54.9±14.7 and 58.3% of patients were male. 69.8% of cases were being dialyzed 3 times a weak and mean duration of each session was 3.78±0.35.hr.73.9% of patients had Kt/v ratio greater than 1.2 and also 72.7% had URR greater than 65%.Dialysis in adequacy had significant relation- ship to hypoALBUMINemia (p<0.001).Conclusion: DIALYSIS adequacy was lower in comparison with US studies but it is better than published papers in Iran, for example Kashan and Hamedan, next studies is necessary to improve DIALYSIS adequacy and have better achievement.

Cites

References

Cite

APA: Copy

MONFARED, ALI, OURANGPOUR, R., & KOHANI, M.. (2008). EVALUATION OF HEMODIALYSIS ADEQUENCY ON PATIENTS UNDERGOING HEMODIALYSIS IN RAZI HOSPITAL IN RASHT. JOURNAL OF GUILAN UNIVERSITY OF MEDICAL SCIENCES, 17(65), 44-49. SID. https://sid.ir/paper/39865/en

Vancouver: Copy

MONFARED ALI, OURANGPOUR R., KOHANI M.. EVALUATION OF HEMODIALYSIS ADEQUENCY ON PATIENTS UNDERGOING HEMODIALYSIS IN RAZI HOSPITAL IN RASHT. JOURNAL OF GUILAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2008;17(65):44-49. Available from: https://sid.ir/paper/39865/en

IEEE: Copy

ALI MONFARED, R. OURANGPOUR, and M. KOHANI, “EVALUATION OF HEMODIALYSIS ADEQUENCY ON PATIENTS UNDERGOING HEMODIALYSIS IN RAZI HOSPITAL IN RASHT,” JOURNAL OF GUILAN UNIVERSITY OF MEDICAL SCIENCES, vol. 17, no. 65, pp. 44–49, 2008, [Online]. Available: https://sid.ir/paper/39865/en

Related Journal Papers

Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top