مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,329
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ASSESSMENT OF A TENTATIVE NOVEL X-RAY ANODE IN DECREASING ITS APPLICABILITY LIMITATION IN MEDICAL PRACTICES

Pages

  8-14

Keywords

Abstract

 Introduction: More than 99% of electrical energy in diagnostic X-Ray tubes converts to heat. This process causes limitation in medical applicability especially in higher intensity for diagnostic and treatment purposes.Objective: To decrease the applicability limitation in x-ray generation via higher cooling rateMaterials and Methods: In this study, a novel anode was proposed with special geometric design and use of new materials in order to obtain higher cooling rate. In doing so, a conventional anode with 9 Cm diameter and 127 Cm2 area, was compared with the proposed anode made of an alloy of chromium, copper and silver with 27 Cm diameter and 1145 Cm2 equipped with a tungsten ring in the same condition. Both anodes were placed inside a container without air flow and heated up to 1200oC using a plasma flame. Then, the anode temperatures were measured and recorded during cooling using a contact thermometer for three times and finally means and standard deviation and also the respective cooling rates were calculated.Results: In both anodes, the cooling modes were exponential but the cooling rates were respectively different, (approximately 180oC/min for the proposed anode) and (approximately 76oC/min for the conventional one) at 1200oC.Conclusions: In comparison with the conventional anode, the proposed anode has higher strength and higher cooling rate. Therefore, it can lead to lower limitation in selecting exposure factors such as mAs and kVp in medical practices.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    NAVVABPOUR, M., MOLADOUST, H., & NAVVABPOUR, M.. (2011). ASSESSMENT OF A TENTATIVE NOVEL X-RAY ANODE IN DECREASING ITS APPLICABILITY LIMITATION IN MEDICAL PRACTICES. JOURNAL OF GUILAN UNIVERSITY OF MEDICAL SCIENCES, 20(79), 8-14. SID. https://sid.ir/paper/40258/en

    Vancouver: Copy

    NAVVABPOUR M., MOLADOUST H., NAVVABPOUR M.. ASSESSMENT OF A TENTATIVE NOVEL X-RAY ANODE IN DECREASING ITS APPLICABILITY LIMITATION IN MEDICAL PRACTICES. JOURNAL OF GUILAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2011;20(79):8-14. Available from: https://sid.ir/paper/40258/en

    IEEE: Copy

    M. NAVVABPOUR, H. MOLADOUST, and M. NAVVABPOUR, “ASSESSMENT OF A TENTATIVE NOVEL X-RAY ANODE IN DECREASING ITS APPLICABILITY LIMITATION IN MEDICAL PRACTICES,” JOURNAL OF GUILAN UNIVERSITY OF MEDICAL SCIENCES, vol. 20, no. 79, pp. 8–14, 2011, [Online]. Available: https://sid.ir/paper/40258/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button