مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

221
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Pages

  257-265

Keywords

Ionic mobility spectrometry (IMS)Q1

Abstract

 Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components such as water vapor, hydrogen, Acetone which in case of disease changes the amount of them. Some of these substances are highly related to diseases like asthma, lung cancer, Diabetes. In this research work, the detection and measurement of Acetone in breath of diabetics is described using an ion mobility spectrometer with a corona-positive ionization source. Methods: Instrumental parameters such as cell and injection temperatures, drift and corona voltages, carrier and drift gas flow rates, and pulse width were investigated. Under optimum conditions, calibration curve and other figures of merits were determined. Under optimum conditions, the breath of diabetics were sampled by syringe and then injected to IMS. Results: Under optimum experimental conditions, the calibration curve was linear in the range of 10-80 ng. The relative standard deviation for 20 and 50 ng of Acetone with 6 times the measurement were 7. 2 and 6. 2%, respectively. The limits of detection and quantification were 2. 7 and 9 ng, respectively. The developed method has been used satisfactory to determine of Acetone in the breath of diabetics.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Golavar, Benazir, Sheibani, Ali, & TABATABAEE, MASOUMEH. (2019). DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD. JOURNAL OF DIABETES AND METABOLIC DISORDERS, 18(5 ), 257-265. SID. https://sid.ir/paper/413775/en

    Vancouver: Copy

    Golavar Benazir, Sheibani Ali, TABATABAEE MASOUMEH. DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD. JOURNAL OF DIABETES AND METABOLIC DISORDERS[Internet]. 2019;18(5 ):257-265. Available from: https://sid.ir/paper/413775/en

    IEEE: Copy

    Benazir Golavar, Ali Sheibani, and MASOUMEH TABATABAEE, “DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD,” JOURNAL OF DIABETES AND METABOLIC DISORDERS, vol. 18, no. 5 , pp. 257–265, 2019, [Online]. Available: https://sid.ir/paper/413775/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button