مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

327
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Outcomes of Ductus Arteriosus Stenting in Neonates with Pulmonary Valve Atresia and Ventricular Septal Defect

Pages

  172-179

Abstract

 Background: Patent ductus arteriosus (PDA) stenting is an interventional method to supply pulmonary blood flow in patients with ductal dependent pulmonary blood flow. This study was conducted to evaluate neonatal PDA stenting at Shiraz University of Medical Sciences, Shiraz, Iran. Materials and Methods: Thirty neonates with a diagnosis of pulmonary valve atresia and ventricular septal defect (VSD) were included in this study. Neonatal PDA stenting had been performed on them from February 2017 to November 2019 at Shiraz University of Medical Sciences. The mortality rate, stent lumen stenosis and stent redilation and also SpO2 of all the patients were assessed before stenting and one year after and compared with the data from other studies. A CT angiography of the aorta and pulmonary arteries had been performed on ten patients at the age of one year; the McGoon ratio was calculated for them and compared against this ratio at their neonatal angiography. Results: PDA stenting was successful in 23 cases (77%) and non-successful in seven cases (23%); meanwhile, four patients expired during or early after stenting. Regarding the access sites for PDA stenting, 22 PDAs were accessed via the axillary artery, six via the femoral arteries and two via the inferior vena cava using an antegrade approach. SpO2 and the McGoon ratio had improved significantly one year after stenting compared to before, with SpO2 increasing from 54. 43± 6. 54 to 83± 7. 33 and McGoon ratio from 1. 18± 0. 23 to 1. 67± 0. 31. Conclusion: Ductal stenting is an effective and less invasive therapeutic method for increasing arterial O2 saturation and maintaining pulmonary blood flow. Most of our patients had good SpO2 one year after PDA stenting without any additional re-intervention and the McGoon ratio had increased sufficiently in them.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    EDRAKI, M.R., & AMIRGHOFRAN, A.A.. (2021). Outcomes of Ductus Arteriosus Stenting in Neonates with Pulmonary Valve Atresia and Ventricular Septal Defect. IRANIAN SOUTH MEDICAL JOURNAL (ISMJ), 24(3 ), 172-179. SID. https://sid.ir/paper/414376/en

    Vancouver: Copy

    EDRAKI M.R., AMIRGHOFRAN A.A.. Outcomes of Ductus Arteriosus Stenting in Neonates with Pulmonary Valve Atresia and Ventricular Septal Defect. IRANIAN SOUTH MEDICAL JOURNAL (ISMJ)[Internet]. 2021;24(3 ):172-179. Available from: https://sid.ir/paper/414376/en

    IEEE: Copy

    M.R. EDRAKI, and A.A. AMIRGHOFRAN, “Outcomes of Ductus Arteriosus Stenting in Neonates with Pulmonary Valve Atresia and Ventricular Septal Defect,” IRANIAN SOUTH MEDICAL JOURNAL (ISMJ), vol. 24, no. 3 , pp. 172–179, 2021, [Online]. Available: https://sid.ir/paper/414376/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button