مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

790
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF MERSILENE MESH AND AUTOGENOUS FASCIA LATA IN PTOSIS CORRECTION

Pages

  164-170

Keywords

Not Registered.

Abstract

 Purpose: To compare Mersilene mesh and autogenous fascia lata in the management of low function ptosis.Methods: A randomized clinical trial was performed on 31 eyelids with poor levator function.Patients were randomly assigned to two groups: 16 eyelids in the Mersilene mesh group and 15 eyelids in the autogenous fascia lata group.Results: Nine patients with congenital unilateral and 11 patients with bilateral ptosis underwent sling procedure. There was no difference between the two groups in terms of functional (lid fissure height stability) and cosmetic (lid margin contour) results. Dermatochalasis was seen more in the fascia lata group (10 cases) compared to the Mersilene mesh group (2 cases). Extrusion of Mersilene mesh occurred in 2 eyelids.Conclusion: Mersilene mesh has favorable long-term functional results and a low rate of complication. This material may be an alternative to autogenous fascia lata as a suspensory material in ptosis surgery.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SALOUR, S.H., ALE TAHA, M., & BAGHERI, ABAS. (2007). COMPARISON OF MERSILENE MESH AND AUTOGENOUS FASCIA LATA IN PTOSIS CORRECTION. BINA, 12(2 (47)), 164-170. SID. https://sid.ir/paper/42744/en

    Vancouver: Copy

    SALOUR S.H., ALE TAHA M., BAGHERI ABAS. COMPARISON OF MERSILENE MESH AND AUTOGENOUS FASCIA LATA IN PTOSIS CORRECTION. BINA[Internet]. 2007;12(2 (47)):164-170. Available from: https://sid.ir/paper/42744/en

    IEEE: Copy

    S.H. SALOUR, M. ALE TAHA, and ABAS BAGHERI, “COMPARISON OF MERSILENE MESH AND AUTOGENOUS FASCIA LATA IN PTOSIS CORRECTION,” BINA, vol. 12, no. 2 (47), pp. 164–170, 2007, [Online]. Available: https://sid.ir/paper/42744/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button