مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

628
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

HOW DOES DSAEK SURGERY CAN CHANGE CORNEAL BIOMECHANICAL PROPERTIES IN PATIENTS WITH PSEUDOPHAKIC BULLOUS KERATOPATHY

Pages

  117-123

Abstract

 Purpose: To compare corneal biomechanical properties and intraocular pressure (IOP) in eyes with PSEUDOPHAKIC BULLOUS KERATOPATHY (PBK) before and after DESCEMET STRIPPING AUTOMATED ENDOTHELIAL KERATOPLASTY (DSAEK).Methods: This prospective non-randomized intra subject comparative study was conducted on 44 eyes of 22 patients with the diagnosis of PBK who underwent DSAEK in one eye. Intraocular pressure was measured by Goldmannapplanation tonometer (IOP GAT), and central corneal thickness (CCT) was measured by ultrasound pachymetry. The OCULAR RESPONSE ANALYSER (ORA) was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-related intraocular pressure (IOPg), and cornea-compensated intraocular pressure (IOPcc). The same measurements were performed in the normal fellow eyes which served as controls. All measurements were performed preoperatively and six months postoperatively.Results: Mean patient agewas 67±14 years. Mean preoperative CH and CRFvalues in the DSAEK group were 5.77±2.94 and 6.39±2.72 mm Hg, respectively, which were significantly lower than those measured in the control group (8.2±2.47 and 8.43±2.49 mm Hg, respectively, P=0.001 for both comparisons). Postoperatively, CH and CRF demonstrated a significant increase (7.09±3.68 mm Hg, P=0.05 and 8.21±3.84 mm Hg, P=0.03, respectively) in operated eyes approaching the normal values measured in the control eyes.Conclusion: Corneal biomechanicalparameters were significantly lower in PBK eyes as compared to the normal fellow eyes. These metrics significantly increased after DSAEK and reached values measured in the normalfellow eyes.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    FARAMARZI, A., RIKHTEGAR, M.H., & NAJDI, D.. (2016). HOW DOES DSAEK SURGERY CAN CHANGE CORNEAL BIOMECHANICAL PROPERTIES IN PATIENTS WITH PSEUDOPHAKIC BULLOUS KERATOPATHY. BINA, 21(2 (83)), 117-123. SID. https://sid.ir/paper/43009/en

    Vancouver: Copy

    FARAMARZI A., RIKHTEGAR M.H., NAJDI D.. HOW DOES DSAEK SURGERY CAN CHANGE CORNEAL BIOMECHANICAL PROPERTIES IN PATIENTS WITH PSEUDOPHAKIC BULLOUS KERATOPATHY. BINA[Internet]. 2016;21(2 (83)):117-123. Available from: https://sid.ir/paper/43009/en

    IEEE: Copy

    A. FARAMARZI, M.H. RIKHTEGAR, and D. NAJDI, “HOW DOES DSAEK SURGERY CAN CHANGE CORNEAL BIOMECHANICAL PROPERTIES IN PATIENTS WITH PSEUDOPHAKIC BULLOUS KERATOPATHY,” BINA, vol. 21, no. 2 (83), pp. 117–123, 2016, [Online]. Available: https://sid.ir/paper/43009/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button