Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

340
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

SINGLE PASS TECHNIQUE USING 400μM VERSUS 350μM MICROKERATOME HEAD FOR PREPARATION OF DONOR ENDOTHELIAL KERATOPLASTY LENTICULES FROM FRESH WHOLE EYES

Pages

  344-348

Abstract

 Purpose: To compare SINGLE PASS technique for preparation of donor ENDOTHELIAL KERATOPLASTY LENTICULEs from fresh whole eyes using 400mm versus 350mm MICROKERATOME head in three different time intervals.Methods: Precut corneas were prepared for Descemet stripping automated ENDOTHELIAL KERATOPLASTY according to the standard protocol of the Central Eye Bank of Iran and by using either 400 m or 350 m MICROKERATOME heads. The preparation was performed in three different time intervals: less than 30 seconds, 30-50 seconds, and more than 50 seconds. Expected thickness of ENDOTHELIAL KERATOPLASTY LENTICULEs (full thickness of central cornea minus the size of MICROKERATOME head) was measured by ultrasound pachymetry. Final thickness of ENDOTHELIAL KERATOPLASTY LENTICULEs and depth of cut were measured by Visante-Optical Coherence Tomography. ANOVA and Bonferroni tests were used to analyze the results considering the size of MICROKERATOME head and duration of the LENTICULE preparation.Results: The study enrolled 316 precut corneas that were prepared between October 2015 and December 2015. Mean depth of cut using the 350 m MICROKERATOME was not significantly different among 3 time intervals (P=0.405); however, the depth of cut with the 400 m MICROKERATOME was significantly different among the different time interval groups and was significantly increased with pass time lasting more than 50 sec (P=0.014).Conclusion: Single slow pass technique using 400 m MICROKERATOME head is an effective method for preparation of thin donor ENDOTHELIAL KERATOPLASTY LENTICULEs from fresh whole globes.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    REZAEI KANAVI, M., NEMATI, F., CHAMANI, T., KHEIRI, B., & JAVADI, M.A.. (1395). تهیه لنتیکول خلفی برای عمل کراتوپلاستی اندوتلیال از گلوب دهندگان در روش تک گذر با استفاده از تیغه میکروکراتوم 400 میکرونی در مقایسه با تیغه 350 میکرونی. بینا, 21(4 (پی در پی 85)), 344-348. SID. https://sid.ir/paper/43024/en

    Vancouver: Copy

    REZAEI KANAVI M., NEMATI F., CHAMANI T., KHEIRI B., JAVADI M.A.. تهیه لنتیکول خلفی برای عمل کراتوپلاستی اندوتلیال از گلوب دهندگان در روش تک گذر با استفاده از تیغه میکروکراتوم 400 میکرونی در مقایسه با تیغه 350 میکرونی. بینا[Internet]. 1395;21(4 (پی در پی 85)):344-348. Available from: https://sid.ir/paper/43024/en

    IEEE: Copy

    M. REZAEI KANAVI, F. NEMATI, T. CHAMANI, B. KHEIRI, and M.A. JAVADI, “تهیه لنتیکول خلفی برای عمل کراتوپلاستی اندوتلیال از گلوب دهندگان در روش تک گذر با استفاده از تیغه میکروکراتوم 400 میکرونی در مقایسه با تیغه 350 میکرونی,” بینا, vol. 21, no. 4 (پی در پی 85), pp. 344–348, 1395, [Online]. Available: https://sid.ir/paper/43024/en