مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

2,150
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

OPTIMIZATION OF BRAIN MRA WITH CONTRAST INJECTION IN 1.5 T FIELD

Pages

  27-34

Abstract

 Background and purpose: Selection of suitable parameters for BRAIN MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of PARAMAGNETIC CONTRAST MEDIA is recommended. Hence, in present study, we investigated the imaging optimization of brain vessels using contrast media in 1.5 T FIELD.Materials and Methods: For image optimization blood T1 was estimated after the injection of 0.1 mmol/kg of Gd-DTPA and the relative blood signals were measured at T1=300, 600, 900 and 1200ms using TR=20 ms and TE=7 ms parameters. Ernest angle and relative signal increased as the T1 decreased. MRA was obtained in three groups, each including five volunteer patients using parameters TR=20 ms, TE=7 ms and flip angle 10, 20 & 30 degrees in two series without and during contrast injection.Signals of carotid, M.C.A and thorcolar herofili and SD in air were measured and it was shown that in 20 degrees flip angle, C/N was maximum.At the last stage, three series of MRA, without, during c.i. and 15 minutes after c.i where obtained in 20 volunteer patients using parameters TR=20 ms, TE=7 ms and flip angle 20 degrees and calculated C/N.Results: After statistical analysis the highest C/N was observed during c.i MRA. Paired t-student test was performed to compare the differences between the C/N ratios. For clinical purposes one vein and two arterles were graded in 5 definite levels.Conclusion: Results indicated an important effect of PARAMAGNETIC CONTRAST MEDIA on better observing of small arteries and vein. The best quality was taken during c.i, but in some arteries contrast media did not improve the quality of MRA.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    RAFIEI, B., RIAHI ALAM, N., BOLOURI, B., OGHABIAN, M.A., HASHEMI, H., GHENAATI, H., & RAHIMI, S.A.. (2006). OPTIMIZATION OF BRAIN MRA WITH CONTRAST INJECTION IN 1.5 T FIELD. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, 16(54), 27-34. SID. https://sid.ir/paper/44840/en

    Vancouver: Copy

    RAFIEI B., RIAHI ALAM N., BOLOURI B., OGHABIAN M.A., HASHEMI H., GHENAATI H., RAHIMI S.A.. OPTIMIZATION OF BRAIN MRA WITH CONTRAST INJECTION IN 1.5 T FIELD. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2006;16(54):27-34. Available from: https://sid.ir/paper/44840/en

    IEEE: Copy

    B. RAFIEI, N. RIAHI ALAM, B. BOLOURI, M.A. OGHABIAN, H. HASHEMI, H. GHENAATI, and S.A. RAHIMI, “OPTIMIZATION OF BRAIN MRA WITH CONTRAST INJECTION IN 1.5 T FIELD,” JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, vol. 16, no. 54, pp. 27–34, 2006, [Online]. Available: https://sid.ir/paper/44840/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top