مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

940
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECT OF OXIC-SETTLING ANOXIC PROCESS ON OPERATION PARAMETERS AND BIOLOGICAL EXCESS SLUDGE REDUCTION IN SEQUENCING BATCH REACTOR ACTIVATED SLUDGE

Pages

  128-140

Abstract

 Background and purpose: One of the solutions for sludge production is to reduce that viadecreasing the YIELD COEFFICIENT by oxic-settling anoxic process with different oxidation reductionpotential (ORP) in sequencing batch reactor (SBR) activated sludge. Materials and methods: We used 2 SBR REACTORs (20 L volume) that were controlled online. At a steady state in reactors, some parameters such as COD, DO, SVI, ORO, dry solids and moisture ofsludge were tested during 12 months. Finally, YIELD COEFFICIENT and reduction rate of biological excesssludge were studied. Results: At 10-day sludge age, the best removal efficiency of COD (95%) was seen without anysludge bulking problems and the kinetic coefficient Y and Kd were 0. 58        g CODg Biomassand 0. 058   d1, respectively. The anoxic and anaerobic phase of the sludge HOLDING TANK showed that sludge storage after7 hours in the reactor with ORP=-238 decreased the YIELD COEFFICIENT from 0. 58 in the control reactor to0. 25g of biomass in g of COD. Consequently, the excess sludge decreased by almost 60%. On the otherhand, compared to the control reactor (92 ml/g), the SVI reduced to less than 40 ml/g. Conclusion: Using HOLDING TANKs in aerobic conditions with ORP greater than 230mv couldcause appropriate settling and lead to a high efficiency of COD removal from wastewater.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    TAKDASTAN, AFSHIN, KARIMI, FERDOS, & OROOJI, NAGHMEH. (2018). EFFECT OF OXIC-SETTLING ANOXIC PROCESS ON OPERATION PARAMETERS AND BIOLOGICAL EXCESS SLUDGE REDUCTION IN SEQUENCING BATCH REACTOR ACTIVATED SLUDGE. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, 28(162 ), 128-140. SID. https://sid.ir/paper/45055/en

    Vancouver: Copy

    TAKDASTAN AFSHIN, KARIMI FERDOS, OROOJI NAGHMEH. EFFECT OF OXIC-SETTLING ANOXIC PROCESS ON OPERATION PARAMETERS AND BIOLOGICAL EXCESS SLUDGE REDUCTION IN SEQUENCING BATCH REACTOR ACTIVATED SLUDGE. JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2018;28(162 ):128-140. Available from: https://sid.ir/paper/45055/en

    IEEE: Copy

    AFSHIN TAKDASTAN, FERDOS KARIMI, and NAGHMEH OROOJI, “EFFECT OF OXIC-SETTLING ANOXIC PROCESS ON OPERATION PARAMETERS AND BIOLOGICAL EXCESS SLUDGE REDUCTION IN SEQUENCING BATCH REACTOR ACTIVATED SLUDGE,” JOURNAL OF MAZANDARAN UNIVERSITY OF MEDICAL SCIENCES, vol. 28, no. 162 , pp. 128–140, 2018, [Online]. Available: https://sid.ir/paper/45055/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button