مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

820
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE EFFECT OF FLOW DIVIDER ON RESTENOSIS IN STENTED HUMAN CORONARY ARTERY WITH MODELING

Pages

  7-12

Abstract

 Background: Shear stress is known to play a central role in restenosis formation and is sensitive to STENT geometry.Objective: To investigate the effect of flow divider on restenosis in a STENTed human coronary artery.Methods: The present paper describes a qualitative study in which a computational fluid dynamics model to analyze the blood flow in a STENTed human coronary artery was used. STENTs were assumed with real structure and modeled using the commercial software package (Gambit, V2.0). A flow divider is a flexible cylindrical body with different diameters and lengths which is centered within the STENT lumen by means of self-expandable stabilizing arms. The blood flow was modeled as an incompressible Newtonian viscous fluid. Rigid geometric boundary conditions were assumed for all simulations. The governing equations were solved using the commercial software package (Fluent, V6.0.12).Findings: The wall shear stress between STENT struts was sensitive to the flow divider, and the wall shear stress distributions for different types of flow divider were calculated.Conclusion: Application of a flow divider led to noticeable increase in wall shear stress in STENTed segment.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    DEHLAGHI, V., NAJARIAN, S., & TAFAZOLI SHADPOUR, MOHAMMAD. (2008). THE EFFECT OF FLOW DIVIDER ON RESTENOSIS IN STENTED HUMAN CORONARY ARTERY WITH MODELING. JOURNAL OF INFLAMMATORY DISEASES (THE JOURNAL OF QAZVIN UNIVERSITY OF MEDICAL SCIENCES), 12(2 (47)), 7-12. SID. https://sid.ir/paper/49059/en

    Vancouver: Copy

    DEHLAGHI V., NAJARIAN S., TAFAZOLI SHADPOUR MOHAMMAD. THE EFFECT OF FLOW DIVIDER ON RESTENOSIS IN STENTED HUMAN CORONARY ARTERY WITH MODELING. JOURNAL OF INFLAMMATORY DISEASES (THE JOURNAL OF QAZVIN UNIVERSITY OF MEDICAL SCIENCES)[Internet]. 2008;12(2 (47)):7-12. Available from: https://sid.ir/paper/49059/en

    IEEE: Copy

    V. DEHLAGHI, S. NAJARIAN, and MOHAMMAD TAFAZOLI SHADPOUR, “THE EFFECT OF FLOW DIVIDER ON RESTENOSIS IN STENTED HUMAN CORONARY ARTERY WITH MODELING,” JOURNAL OF INFLAMMATORY DISEASES (THE JOURNAL OF QAZVIN UNIVERSITY OF MEDICAL SCIENCES), vol. 12, no. 2 (47), pp. 7–12, 2008, [Online]. Available: https://sid.ir/paper/49059/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button